Holiday Inn - Whirlpool
393 Gregg Avenue Hinton AB T7V 1N1 · Aquatic Facility
15 inspections
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The skimmer cover (lid) is cracked/damaged on the edges.- Please replace the skimmer cover.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Monitoring Inspection
0 infractions
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pump is leaking. Operator advised it started leaking again in January 2025. (Note: the gasket was replaced in Nov 2024). - Operator advised that a new pump has been ordered as replacing the gasket did not solve the problem properly.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was 199 ppm.Please maintain total alkalinity between 60 ppm and 180 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The floating weir (door) of the skimmer is missing. Operator advised the floating weir broke. - Please install a new floating weir to maintain water quality.2. The pump is leaking. Operator advised it started leaking again in January 2025. (Note: the gasket was replaced in Nov 2024). - Operator advised that a new pump has been ordered as replacing the gasket did not solve the problem properly.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Observed water leak from the pump.Operator advised that a new pump has been ordered to replace the leaky pump.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- The flow meter is not in operation. Please fix.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Observed water leak on the secondary anti-entrapment device (safety vacuum release system) attached to the whirlpool pump. May 24: Operator reported the leak was fixed, but the public health inspector (PHI) still observed minor leak coming from the pump or the safety vacuum release system. The operator and the PHI were not able to identify whether the leak was coming from the pump or the safety vacuum release system. ** Please investigate and rectify the leak.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Observed water leak on the secondary anti-entrapment device (safety vacuum release system) attached to the whirlpool pump. Please fix.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Monitoring Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The whirlpool pump was noted to be leaking.Operator purchased a new pump to replace until May 21, 2024.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The anti-entrapment compliance plan for the whirlpool expired. Please update anti-entrapment plan and provide documentation confirming compliance.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- No written policies were developed and maintained for: - general sanitation - response to water quality issues including fecal contaminationPlease develop written policies for general sanitation and for response to water quality incident and implement use.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Unsatisfactory bacteriological water sample, Accession #WE-23-0133014: Pseudomonas aeruginosa isolated. Treat the whirlpool and ensure it is safe prior to reopening of the hot tub.Resample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions