Skip to content
Loading map…

Lindbrook Star Gazer Campground & RV Park - Outdoor Pool

51123 Range Road 200 Beaver County AB T0B 4J1 · Aquatic Facility

13 inspections

  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Unsatisfactory water sample was collected on July 2, 2026Total Coliforms: AbsentHPC: 130 CFU/mLJULY 11, 2026:Heterotrophic Plate Count (HPC) of 150 for the sample collected from the outdoor pool on July 7, 2026 and which exceeds our threshold of maximum 100 for HPC and ideally should be less than 10.Based on this test result, our Department would recommend a super chlorination of the outdoor pool and another resample to verify the HPC has been resolved to satisfactory levels.
  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Unsatisfactory water sample was collected on July 2, 2026Total Coliforms: AbsentHPC: 130 CFU/mL
  3. Risk Management Inspection

    0 infractions

  4. Monitoring Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HETEROTROPHIC PLATE COUNT (HPC) OF 18, 630 FOR THE OUTDOOR POOL:Collected on May 26, 2026 and results were known on May 29, 2026.Not in compliance and HPC should be 100 or less and ideally less than 10.Please follow-up with the appropriate action.UPDATE ON FRIDAY JUNE 5, 2026:Bacteriological water sample collected on June 2, 2026 following the shock chlorination over the past weekend showed Heterotrophic Plate Count of >57,000 which is unsatisfactory for aquatic facilities.Based on this test result, the shock chlorination procedure requires repeating and resampling next Tuesday June 9 to confirm the issue has been fully resolved.
  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HETEROTROPHIC PLATE COUNT (HPC) OF 18, 630 FOR THE OUTDOOR POOL:Collected on May 26, 2026 and results were known on May 29, 2026.Not in compliance and HPC should be 100 or less and ideally less than 10.Please follow-up with the appropriate action.UPDATE ON FRIDAY JUNE 5, 2026:Bacteriological water sample collected on June 2, 2026 following the shock chlorination over the past weekend showed Heterotrophic Plate Count of >57,000 which is unsatisfactory for aquatic facilities.Based on this test result, the shock chlorination procedure requires repeating and resampling next Tuesday June 9 to confirm the issue has been fully resolved.
  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HETEROTROPHIC PLATE COUNT (HPC) OF 18, 630 FOR THE OUTDOOR POOL:Collected on May 26, 2026 and results were known on May 29, 2026.Not in compliance and HPC should be 100 or less and ideally less than 10.Please follow-up with the appropriate action.
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic Plate Count (HPC) of 200 was found in the outdoor pool and maximum threshold is 100 or less.Would encourage the operator to move forward with the increase/shock chlorinate the chlorine to lower the HPC to satisfactory levels (and ideally should be less than 10).JULY 25, 2025:Heterotrophic Plate Count (HPC) of 140 for the sample collected on July 22, 2025 - exceeds the threshold of <100 and ideally should be <10.Please take the appropriate action to reduce the above levels to satisfactory levels of at least <100.AUGUST 15, 2025 UPDATE:Bacteriological water sample collected from the outdoor pool on August 12, 2025 was Heterotrophic Plate Count of 1590 which exceeds the threshold of maximum <100 and ideally should always be less than 10.Please take immediate action as necessary to lower these counts to satisfactory levels.Finally, resample the outdoor pool next Tuesday August 19, 2025 and test result will dictate next step.
  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic Plate Count (HPC) of 200 was found in the outdoor pool and maximum threshold is 100 or less.Would encourage the operator to move forward with the increase/shock chlorinate the chlorine to lower the HPC to satisfactory levels (and ideally should be less than 10).JULY 25, 2025:Heterotrophic Plate Count (HPC) of 140 for the sample collected on July 22, 2025 - exceeds the threshold of <100 and ideally should be <10.Please take the appropriate action to reduce the above levels to satisfactory levels of at least <100.
  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic Plate Count (HPC) of 200 was found in the outdoor pool and maximum threshold is 100 or less.Would encourage the operator to move forward with the increase/shock chlorinate the chlorine to lower the HPC to satisfactory levels (and ideally should be less than 10).
  11. Monitoring Inspection

    0 infractions

  12. Monitoring Inspection

    0 infractions

  13. Demand Inspection

    0 infractions