Skip to content
Loading map…

Mountain View Inn & Suites - Hot Tub

706 Main Avenue E Sundre AB T0M 1X0 · Aquatic Facility

Inspection summary

Mountain View Inn & Suites - Hot Tub has been inspected 26 times by Alberta Health Services (Environmental Public Health) since November 24, 2023. The most recent inspection, on July 24, 2026, found no infractions.

10 of 26 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The last 2 inspections in a row found no infractions. The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 15 times across 13 separate inspections, most recently on August 11, 2025. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 3 times across 3 separate inspections, most recently on March 5, 2026. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

26 inspections

  1. Monitoring Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Monitoring Inspection

    1 infraction

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. Several of the water test kit reagents were expired. - DPD3, AlkReplace the expired chemical reagents.
  4. Monitoring Inspection

    1 infraction

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. Several of the water test kit reagents were expired. - DPD3, Phenol Red, AlkReplace the expired chemical reagents.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Routine water sample result: TC PresentPlease resample to confirm test result. Make sure to mark the bottle as "Resample".
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Routine water sample result: TC PresentPlease resample to confirm test result. Make sure to mark the bottle as "Resample".
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • TC Present.
  11. Risk Management Inspection

    0 infractions

  12. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. The turnover time for the hot tup is too slow. It must be 20 minutes or less. Increase the circulation flow rate to create a turnover time of 20 minutes or less.Vol: 759 usgFlow: 30 gpmTurnover: 25 minNote: the minimum flow rate to meet a 20 minute turnover is 38 gpmAn automated control system is installed and functioning.
  13. Risk Management Inspection

    0 infractions

  14. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • TC Present.
  15. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • TC Present.
  16. Monitoring Inspection

    1 infraction

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. The water test kit reagents were expired.Water chemistry was tested and recorded regularly during daily operation.The water chemistry records were reviewed during the inspection.
  17. Risk Management Inspection

    0 infractions

  18. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Routine water sample result: TC PresentPlease resample to confirm test result. Make sure to mark the bottle as "Resample".
  19. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas isolated from May 22, 2024 sample submission. Operator, Kevin, will close the hot tub and take pseudomonas response protocols immediately and will resample as per usual this week.
  20. Risk Management Inspection

    0 infractions

  21. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Turnover: Volume 759 Gal (2873 liters). Hot tubs <4000L require turnovers every 15 minutes or 96 times a day Min flow rate 759 gal/.25 hours/60 min/hour = 50.6 gpm is what the hot tub needs to run at to meet the 15 minute turnover rate. Measured flow rate Flow 40 gpmThe hot tub is currently turning over every 759 gal/40 gpm = 18.9 minutes. Increase the flow of the hot tub to at least 50 gpm to meet the required number of turnovers. Please adjust the flow immediately.
  22. Risk Management Inspection

    0 infractions

  23. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow 45 gpmFiltrationTriton II TR 100 high-rate sand filter in place. As per manufacturer’s spec plate: Filtration flow rate 74 gpm, filtration area 4.91 sq ft, max rate of filtration 15 gpm/sq ft. Maximum rate of filtration 45 gpm / 4.91 sq ft = 9.2 gpm/sq foot which is within the max rate of filtration of 12.5 US gpm/sq ft. in the which exceeds the manufacturer's specs and Pool StandardsTurnover: Volume 759 Gal (2873 liters). Hot tubs <4000L require turnovers every 15 minutes or 96 times a day Min flow rate 759 gal/.25 hours/60 min/hour = 50.6 gpmMeasured flow rate Flow 45 gpmAction:Please increase the flow to 50 gpm to meet the 15 minute turnover requirement. This will increase the maximum rate of filtration to 10 gpm/sq foot which is still within range of the filter specs.
  24. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas isolated from water sample that was collected on December 27, 2023. Operator, Kevin Gamble notified by email and phone call. Results and pseudo information sheet provided.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow 45 gpmFiltrationTriton II TR 100 high-rate sand filter in place. As per manufacturer’s spec plate: Filtration flow rate 74 gpm, filtration area 4.91 sq ft, max rate of filtration 15 gpm/sq ft. Maximum rate of filtration 45 gpm / 4.91 sq ft = 9.2 gpm/sq foot which is within the max rate of filtration of 12.5 US gpm/sq ft. in the which exceeds the manufacturer's specs and Pool StandardsTurnover: Volume 759 Gal (2873 liters). Hot tubs <4000L require turnovers every 15 minutes or 96 times a day Min flow rate 759 gal/.25 hours/60 min/hour = 50.6 gpmMeasured flow rate Flow 45 gpmAction:Please increase the flow to 50 gpm to meet the 15 minute turnover requirement. This will increase the maximum rate of filtration to 10 gpm/sq foot which is still within range of the filter specs.
  25. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow 45 gpmFiltrationTriton II TR 100 high-rate sand filter in place. As per manufacturer’s spec plate: Filtration flow rate 74 gpm, filtration area 4.91 sq ft, max rate of filtration 15 gpm/sq ft. Maximum rate of filtration 45 gpm / 4.91 sq ft = 9.2 gpm/sq foot which is within the max rate of filtration of 12.5 US gpm/sq ft. in the which exceeds the manufacturer's specs and Pool StandardsTurnover: Volume 759 Gal (2873 liters). Hot tubs <4000L require turnovers every 15 minutes or 96 times a day Min flow rate 759 gal/.25 hours/60 min/hour = 50.6 gpmMeasured flow rate Flow 45 gpmAction:Please increase the flow to 50 gpm to meet the 15 minute turnover requirement. This will increase the maximum rate of filtration to 10 gpm/sq foot which is still within range of the filter specs.
  26. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total coliforms present. Operator notified by email, text and call. Operator will follow pseudo protocol as proactive measure.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow 45 gpmFiltrationTriton II TR 100 high-rate sand filter in place. As per manufacturer’s spec plate: Filtration flow rate 74 gpm, filtration area 4.91 sq ft, max rate of filtration 15 gpm/sq ft. Maximum rate of filtration 45 gpm / 4.91 sq ft = 9.2 gpm/sq foot which is within the max rate of filtration of 12.5 US gpm/sq ft. in the which exceeds the manufacturer's specs and Pool StandardsTurnover: Volume 759 Gal (2873 liters). Hot tubs <4000L require turnovers every 15 minutes or 96 times a day Min flow rate 759 gal/.25 hours/60 min/hour = 50.6 gpmMeasured flow rate Flow 45 gpmAction:Please increase the flow to 50 gpm to meet the 15 minute turnover requirement. This will increase the maximum rate of filtration to 10 gpm/sq foot which is still within range of the filter specs.

Nearby inspected facilities

Own this business? Add a badge to your website