Pamper me by Joan
39 Tararidge Place NE Calgary AB T3J 2R5 · Personal Services
3 inspections
- Risk Management Inspection
1 infraction
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- The facility does not have written, facility-specific procedures addressing critical aspects of client care, such as response to accidental cuts or punctures, cleansing of skin and mucous membranes, and the application of antiseptic products.The operator must develop and implement facility-specific written procedures covering client care in the event of accidental skin cuts or punctures, cleansing of skin and mucous membranes, use of antiseptic products, and any other procedures relevant to the services offered at the home-based personal service.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- Risk Management Inspection
3 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- The facility does not have written, facility-specific procedures addressing critical aspects of client care, such as response to accidental cuts or punctures, cleansing of skin and mucous membranes, and the application of antiseptic products.The operator must develop and implement facility-specific written procedures covering client care in the event of accidental skin cuts or punctures, cleansing of skin and mucous membranes, use of antiseptic products, and any other procedures relevant to the services offered at the home-based personal service.
- 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
- 1. A mirror was present in the laser treatment room, creating potential for unintended laser beam reflections and increased risk of accidental exposure. The presence of reflective surfaces is not in accordance with the manufacturer’s safety guidelines for laser equipment.Remove the mirror from the service room.
- 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
- Laser services are being provided in a room with a window and sliding door that, although covered by blinds, do not meet laser safety requirements for containment which require treatment rooms to be properly sealedProvide confirmation from the laser device manufacturer verifying that this room configuration complies with the device’s safety requirements. Discontinue services in the mean time.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- Monitoring Inspection
6 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- The facility does not have written, facility-specific procedures addressing critical aspects of client care, such as response to accidental cuts or punctures, cleansing of skin and mucous membranes, and the application of antiseptic products.The operator must develop and implement facility-specific written procedures covering client care in the event of accidental skin cuts or punctures, cleansing of skin and mucous membranes, use of antiseptic products, and any other procedures relevant to the services offered at the home-based personal service.
- 20. Is reusable equipment disinfected properly?
- CS20 high-level disinfectant solution is being used to reprocess semi-critical tools without routine testing to verify its concentration and effectiveness. No test strips were available on site to confirm the solution remains active.Obtain and use appropriate test strips to check the concentration of the CS20 solution according to the manufacturer’s instructions. Testing must be performed each time the solution is used, and records must be maintained for the test conducted.
- 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
- Laser services are being provided in a room with a window and sliding door that, although covered by blinds, do not meet laser safety requirements for containment which require treatment rooms to be properly sealedProvide confirmation from the laser device manufacturer verifying that this room configuration complies with the device’s safety requirements. Discontinue services in the mean time.
- 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
- 1. A mirror was present in the laser treatment room, creating potential for unintended laser beam reflections and increased risk of accidental exposure. The presence of reflective surfaces is not in accordance with the manufacturer’s safety guidelines for laser equipment.Remove the mirror from the service room.
- 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
- There was no designated work surface in the reprocessing area to support proper cleaning and disinfection of tools.The operator must provide a smooth, non-absorbent, and easily cleanable work surface in the reprocessing area to allow for safe and effective cleaning, disinfection, and drying of reusable instruments and tools.
- 32. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Critical)?
- Microneedling needles were found to be missing lot number identification and expiry date.Discard the needles. Obtain needles with lot and expiry. Records of these details must be maintained with client information to support traceability.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?