Quality Inn & Suites - Pool
4070 2 Avenue S Lethbridge AB T1J 3Z2 · Aquatic Facility
10 inspections
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
3 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be a bit low at 55 ppm.Please ensure that the alkalinity is maintained between 60-180 ppm at all times.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of >57000 CFU/mL was isolated in the October 28 sample. Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be a bit low at 55 ppm.Please ensure that the alkalinity is maintained between 60-180 ppm at all times.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
3 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be a bit low at 55 ppm.Please ensure that the alkalinity is maintained between 60-180 ppm at all times.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Total coliforms were present in the sample collected August 25.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be a bit low at 55 ppm.Please ensure that the alkalinity is maintained between 60-180 ppm at all times.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
3 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be a bit low at 55 ppm.Please ensure that the alkalinity is maintained between 60-180 ppm at all times.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
5 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity concentration in the pool was measured to be 18 ppm.Please ensure that the total alkalinity concentration is maintained at a level between 60 and 180 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter was broken. Please ensure that there is an operational flow meter to adequately monitor the filtration rate of the pool.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- There were pools of standing water with growth of biofilm observed on the deck near the slide. The air conditioning duct above had a considerable amount of condensation that was contributing to the standing water. There was dark discolouration on the top and bottom of the water slide.Please ensure that any standing water on the deck is monitored and cleaned regularly to prevent the growth of biofilm. Please ensure that the water slide is cleaned regularly to prevent the growth of bacteria that may lead to discolouration.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
5 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity concentration in the pool was measured to be 18 ppm.Please ensure that the total alkalinity concentration is maintained at a level between 60 and 180 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter was broken. Please ensure that there is an operational flow meter to adequately monitor the filtration rate of the pool.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- There were pools of standing water with growth of biofilm observed on the deck near the slide. The air conditioning duct above had a considerable amount of condensation that was contributing to the standing water. There was dark discolouration on the top and bottom of the water slide.Please ensure that any standing water on the deck is monitored and cleaned regularly to prevent the growth of biofilm. Please ensure that the water slide is cleaned regularly to prevent the growth of bacteria that may lead to discolouration.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
6 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The temperature of the pool was recorded to be over 30°C and bacteriological water samples are not being tested for the presence of pseudomonas. Aquatic facilities that maintain the temperature of their water over 30°C need to monitor for the growth of pseudomonas when submitting bacteriological water samples.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity concentration in the pool was measured to be 18 ppm.Please ensure that the total alkalinity concentration is maintained at a level between 60 and 180 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter was broken. Please ensure that there is an operational flow meter to adequately monitor the filtration rate of the pool.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There were no weirs present in the skimmers. Please ensure that all skimmers have weirs to prevent debris from being re-introduced into the pool.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- There were pools of standing water with growth of biofilm observed on the deck near the slide. The air conditioning duct above had a considerable amount of condensation that was contributing to the standing water. There was dark discolouration on the top and bottom of the water slide.Please ensure that any standing water on the deck is monitored and cleaned regularly to prevent the growth of biofilm. Please ensure that the water slide is cleaned regularly to prevent the growth of bacteria that may lead to discolouration.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Chemical testing for the concentration of total alkalinity is not being performed.Please ensure that chemical testing for total alkalinity is being performed at least once per week and recorded to maintain the proper chemical concentrations and water quality.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions