Best Western Plus Service Inn & Suites 61094 - Whirlpool
209 41 Street S Lethbridge AB T1J 1Z3 · Aquatic Facility
Inspection summary
Best Western Plus Service Inn & Suites 61094 - Whirlpool has been inspected 25 times by Alberta Health Services (Environmental Public Health) since December 6, 2023. The most recent inspection, on September 21, 2026, found no infractions.
8 of 25 inspections on record found no infractions at all. In the past 12 months there were 8 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 23 times across 16 separate inspections, most recently on September 13, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 3 times across 2 separate inspections, most recently on February 25, 2025. For example:
Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
25 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Pseud positive hot tub
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Recent bacteriological water sample yielded an unsatisfactory result: Pseudomonas aeruginosa isolated.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 1950 CFU/mL was isolated in the sample collected June 25. Please address the HPC in the whirlpool and submit a resample once complete.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- There was a piece of tile missing along the edge of the main drain cover. Where the tile was attached there was now an opening along the bottom of the cover for the drain which could cause suction/entrapment issues. This was pointed out to the operator who was able to fashion a piece of hard foam into the size and shape of the missing tile. This was then wedged into the space as a temporary fix until the tile could be reattached. The operator indicated that this could be repaired fully by Friday. A reinspection will take place then.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Total coliforms were present in sample collected May 22.As this is the second consecutive water sample with bad results, a Closure Order was issued for the whirlpool until a sample is received that is clear of Total coliforms, HPC and Pseudomonas.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Pseudomonas aeruginosa was isolated in the sample collected May 15. Pseudomonas aeruginosa was isolated in the sample collected May 22.Please initiate Pseudomonas protocols and submit a resample once complete. A Closure Order was issued for the whirlpool until a sample comes back clear of Pseudomonas, Total coliforms and HPC.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC 2560 CFU/mL was isolated in the sample collected May 15. An HPC of >57000 CFU/mL was isolated in the sample collected May 22.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- psudamonas in sample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC count of 2560
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine level was high at 1.41 ppm. The operator indicated that tomorrow (Wednesday) is their regular day to drain and clean the hot tub. This should address the combined chlorine level. For bather comfort, the combined chlorine level should be kept as low as possible, and at least below 1.0 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC count of 130 is above the threshold of <100 CFU/mL. It appears to be a sampling error. Advised the operator to ensure samples are taken properly to prevent contamination.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the hot tub was not operational at the time of the inspection. Please repair.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Pseudomonas present in sample taken on May 2, 2024.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Pseudomonas aeruginosa was isolated in the March 21 sample. Please initiate Pseudomonas protocols and submit a resample once complete.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 1220 CFU/mL was isolated in the sample collected March 21. Please address the HPC in the hot tub and submit a resample once complete
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 230 CFU/mL was isolated in the sample collected February 22. Please address the HPC in the whirlpool and submit a resample once complete.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The chlorine level in the hot tub was measured at 0.74 ppm. Please ensure the chlorine level is maintained at 2.0 ppm or higher at all times. *Operator drained the whirlpool and backwashed the system during the inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine level in the hot tub was measured at 2.38 ppm. Please shock the whirlpool to bring this level down below 1.0 ppm. The combined chlorine level should be maintained as far below 1.0 ppm as possible for bather comfort.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
Nearby inspected facilities
- Best Western Plus Service Inn & Suites 61094 - Pool
209 41 Street S Lethbridge AB T1J 1Z3
19 inspections
- Best Western Plus Service Inn & Suites - 61094
209 41 Street S Lethbridge AB T1J 1Z3
2 inspections
- Best Western Plus Service Inn & Suites 61094 - Common Area
209 41 Street S Lethbridge AB T1J 1Z3
3 inspections
- Holiday Inn Express Lethbridge SE - Breakfast
217 41 Street S Lethbridge AB T1J 1Z3
2 inspections
- Holiday Inn Express Lethbridge SE - Pool
217 41 Street S Lethbridge AB T1J 1Z3
28 inspections
- Holiday Inn Express Lethbridge SE - Common Area
217 41 Street S Lethbridge AB T1J 1Z3
3 inspections
- Holiday Inn Express Lethbridge SE - Whirlpool
217 41 Street S Lethbridge AB T1J 1Z3
39 inspections
- Fairfield Inn & Suites - Whirlpool
4081 2 Avenue S Lethbridge AB T1J 1Z2
16 inspections