Shawnessy YMCA - Whirlpool

333 Shawville Boulevard SE Calgary AB T2Y 4H3 · Aquatic Facility

13 inspections

  1. Demand Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The sample submitted on February 24, 2026 was not processed because the time of collection was not indicated on the sample.Please submit a re‑sample and ensure all required information is completed.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample dated January 13, 2026 was unsatisfactory due to a high HPC value of 110 CFU/mL.Please submit a re-sample.
  5. Monitoring Inspection

    0 infractions

  6. Demand Inspection

    0 infractions

  7. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on December 17/24 had Pseudomonas isolated. - Superchlorinate the whirlpool water, drain water, clean the basin, refill, balance and submit a resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine level was high at 2.1 ppm. Operating records shows that combined chlorine is consistently over 1 ppm but no actions are being taken. -Maintain combined chlorine at the lowest level possible.
  8. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine level was high at 2.1 ppm. Operating records shows that combined chlorine is consistently over 1 ppm but no actions are being taken. -Maintain combined chlorine at the lowest level possible.
  9. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine level was high at 2.1 ppm. Operating records shows that combined chlorine is consistently over 1 ppm but no actions are being taken. -Maintain combined chlorine at the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Could not locate model information on the new filters. The data plates did not indicate model of the filters so surface area is unknown and max filtration rate could not be calculated. - Provide the information
  10. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • July 30 sample was cancelled by lab due to staples used on requisition/baggie. Emailed Rizal to submit resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Total alkalinity measure 38 gpm. - Maintain total alkalinity between 60-180 gpm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. The flow meter for the jet pump was not working.- Please repair/replace flow meter
  11. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Total alkalinity measure 38 gpm. - Maintain total alkalinity between 60-180 gpm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. The flow meter for the jet pump was not working.- Please repair/replace flow meter
  12. Risk Management Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. The flow meter for the jet pump was not working.2. The flow rate for the whirlpool measured at 283gpm which exceeds the max capacity of the filter (2 x 140) = 280gpm1. Please repair/replace flow meter2. Please adjust and maintain flow rate within the filter max capacity as indicated by the manufacturer
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The skimmers in the hot tub had grime build up on the walls1. Clean skimmers2. Ensure that skimmers are checked and cleaned on a daily basis
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The floating skimmer weir in the whirlpool was brokenPlease repair floating weir
  13. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. July 25, 2023 sample - Pseudomonas isolated.- Operator will treat and resample today.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. The flow meter for the jet pump was not working.2. The flow rate for the whirlpool measured at 283gpm which exceeds the max capacity of the filter (2 x 140) = 280gpm1. Please repair/replace flow meter2. Please adjust and maintain flow rate within the filter max capacity as indicated by the manufacturer
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The skimmers in the hot tub had grime build up on the walls1. Clean skimmers2. Ensure that skimmers are checked and cleaned on a daily basis
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The floating skimmer weir in the whirlpool was brokenPlease repair floating weir