SKA Thermal Spa - Cold Pool

117 - 638 11 Avenue SW Calgary AB T2R 0E2 · Aquatic Facility

Inspection summary

SKA Thermal Spa - Cold Pool has been inspected 6 times by Alberta Health Services (Environmental Public Health) since May 15, 2024. The most recent inspection, on July 17, 2026, recorded 1 infraction.

1 of 6 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 2 infractions recorded. The higher-risk findings here relate to: Chemicals and toxic substances and Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 3 times across 3 separate inspections, most recently on July 17, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 3 times across 2 separate inspections, most recently on October 24, 2024. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

6 inspections

  1. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was measured at 2.29 ppm. Chlorine smell was present. - Keep combined chlorine levels as low as possible to provide maximum comfort to batters. Encourage bather to shower before using the cold pool, continue to do the daily dilutions, and possibly look into a secondary disinfection method to lower the combined chlorine.Recommend changing the cartridges in the filter to see if the water quality improves.
  2. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was measured at 2 ppm. Chlorine smell was present. - Keep combined chlorine levels as low as possible to provide maximum comfort to batters. Encourage bather to shower before using the cold pool, continue to do the daily dilutions, and possibly look into a secondary disinfection method to lower the combined chlorine.
  3. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was measured at 5.36 ppm. Please keep combined chlorine levels as low as possible to provide maximum comfort to batters. Encourage bather to shower before using the cold pool, continue to do the daily dilutions, and possibly look into a secondary disinfection method to lower the combined chlorine.
  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken Oct 22, 2024 - HPC 120 CFU/mL.-Resample
  5. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample taken July 30, 2024 - total coliforms present.-Treat and resample
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken July 30, 2024 - HPC 370 CFU/mL.-Resample
  6. Monitoring Inspection

    0 infractions