Inspection summary

Solano Footcare has been inspected 2 times by Alberta Health Services (Environmental Public Health) since July 26, 2024. The most recent inspection, on September 8, 2025, recorded 2 infractions.

1 of 2 inspections on record found no infractions at all. No inspections are on record from the past 12 months. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 2 times on September 8, 2025. For example: Is reusable equipment handled and stored properly (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

2 inspections

  1. Monitoring Inspection

    2 infractions

    • 15. Is reusable equipment handled and stored properly (Critical)?
      • The operator’s reusable equipment includes curettes and nippers.The operator currently stores dirty reusable items in a dry container and soaks them at home later.Please ensure enzymatic cleaner is brought with you, and is placed in soaking containers before placing dirty equipment in them. This will ensure the instruments remain soaking after use, allowing for easier and more effective cleaning.---The operator also performs a sterilization step in a pressure cooker–type, autoclave machine for medical device sterilization, after using HLD; however, it was discussed that this step is unnecessary. It is recommended that this step not be performed, as the device is not an approved sterilizer and the temperature cannot be verified, providing no guarantee of sterility and potentially introducing contamination.
    • 20. Is reusable equipment disinfected properly?
      • The operator explained that she cleans equipment with enzymatic cleaner, rinses with water, and submerges items in HLD5 for 5 minutes without drying prior to disinfection.Please ensure thorough drying of equipment before disinfection to prevent the possibility of diluting the HLD5 with water.---HLD5 is an approved high-level disinfectant, was not expired, and the operator had test strips capable of confirming it is at the sufficient concentration of 2% prior to each day’s use.The operator records this daily, and logs are maintained on site.