Super 8 - Swimming Pool

10050 116 Avenue Grande Prairie AB T8V 4K5 · Aquatic Facility

29 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample taken March 31, 2026: HPC >57,000HPC must be below 100 cfu/100mlAssess treatment system performance, confirm water chemistry is within operating parameters, and resample.
  3. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample taken March 31, 2026: HPC >57,000HPC must be below 100 cfu/100mlAssess treatment system performance, confirm water chemistry is within operating parameters, and resample.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.December 15, 2025: Combined chlorine is not tested and recorded daily.
  4. Risk Management Inspection

    1 infraction

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.December 15, 2025: Combined chlorine is not tested and recorded daily.
  5. Risk Management Inspection

    1 infraction

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.December 15, 2025: Combined chlorine is not tested and recorded daily.
  6. Risk Management Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3 C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30 C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30 CDecember 15, 2025: The water temperature is noted to be 32.7 C.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some debris (sand particles) were observed at the bottom of the swimming pool basin.Ensure bottom of the swimming pool basin is cleaned prior to opening of the pool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The deck floor is not clean. Some hair and stains were noted during the inspection.Ensure deck floor is cleaned before opening of the pool.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.December 15, 2025: Combined chlorine is not tested and recorded daily.
  7. Monitoring Inspection

    6 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample was collected on December 10, 2025.Total Coliforms: PresentEnsure pool shock chlorinated and water chemistry is balanced before submitting a water sample next week.December 15, 2025: Ensure the pool remains closed until satisfactory water results are received from the laboratory.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample submitted on December 10. 2025 has HPC >57,000.Ensure pool remains closed until satisfactory HPC results are received.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3 C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30 C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30 CDecember 15, 2025: The water temperature is noted to be 32.7 C.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The deck floor is not clean. Some hair and stains were noted during the inspection.Ensure deck floor is cleaned before opening of the pool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some debris (sand particles) were observed at the bottom of the swimming pool basin.Ensure bottom of the swimming pool basin is cleaned prior to opening of the pool.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.December 15, 2025: Combined chlorine is not tested and recorded daily.
  8. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample was collected on December 10, 2025.Total Coliforms: PresentEnsure pool shock chlorinated and water chemistry is balanced before submitting a water sample next week.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30C
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • The pool permit was not available during the inspection.The pool permit must be posted in the pool.Ensure that the pool permit is displayed at all times, and it is conspicuous to patrons.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The Berkeley pump was noted to be leaking.Ensure that the pump is in good repair at all times.The operator indicated that plans are in place for a replacement.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.
  9. Risk Management Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30C
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • The pool permit was not available during the inspection.The pool permit must be posted in the pool.Ensure that the pool permit is displayed at all times, and it is conspicuous to patrons.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The Berkeley pump was noted to be leaking.Ensure that the pump is in good repair at all times.The operator indicated that plans are in place for a replacement.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.
  10. Demand Inspection

    5 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample was collected on November 12, 2025.HPC: >57,000 CFU/mLHPC count must be less than 100 CFU/mL. Ensure pool shock chlorinated and water chemistry is balanced before submitting a water sample this week.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30C
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • The pool permit was not available during the inspection.The pool permit must be posted in the pool.Ensure that the pool permit is displayed at all times, and it is conspicuous to patrons.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The Berkeley pump was noted to be leaking.Ensure that the pump is in good repair at all times.The operator indicated that plans are in place for a replacement.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.
  11. Risk Management Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30C
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • The pool permit was not available during the inspection.The pool permit must be posted in the pool.Ensure that the pool permit is displayed at all times, and it is conspicuous to patrons.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The Berkeley pump was noted to be leaking.Ensure that the pump is in good repair at all times.The operator indicated that plans are in place for a replacement.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.
  12. Demand Inspection

    5 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample was collected on June 18, 2025.HPC: >57,000 cfu/mLPool operator stated that pool is currently closed due to fecal contamination and will be shock chlorinated. HPC count must be less than 100 cfu/mL. Ensure pool is closed during shock chlorination and water chemistry balanced before submitting a water sample this week.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30C
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • The pool permit was not available during the inspection.The pool permit must be posted in the pool.Ensure that the pool permit is displayed at all times, and it is conspicuous to patrons.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The Berkeley pump was noted to be leaking.Ensure that the pump is in good repair at all times.The operator indicated that plans are in place for a replacement.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.
  13. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was noted at 33.3C without weekly testing for Pseudomonas Ensure if the pool water temperature is kept above 30C that the water is sampled weekly for pseudomonas in addition to total coliforms and HPC, otherwise pool water temperature must be lowered to below 30C
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • The pool permit was not available during the inspection.The pool permit must be posted in the pool.Ensure that the pool permit is displayed at all times, and it is conspicuous to patrons.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The Berkeley pump was noted to be leaking.Ensure that the pump is in good repair at all times.The operator indicated that plans are in place for a replacement.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Combined chlorine is not tested and recorded.Ensure combined chlorine is tested and recorded daily.
  14. Risk Management Inspection

    0 infractions

  15. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample was collected on May 14, 2025HPC: >57,000 cfu/mLPool operator stated that pool is currently closed and will be shock chlorinated. Believes that it's due to pool parties. Operator was instructed to ensure that bather load does not exceed. HPC count must be less than 100 cfu/mL. Ensure pool is closed during shock chlorination and water chemistry balanced before submitting a water sample this week.
  16. Risk Management Inspection

    0 infractions

  17. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Written plans/procedures were not available for water quality incident responses.Please ensure written plans/procedures are established and maintained for water quality incident responses.
  18. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water results are unsatisfactory:- HPC: 250 cfu/mLPool operator indicated that the chlorine tank / pump ran out of chlorine. There was a high bather load in the pool as well. Once all issues have been addressed, shock the pool, rebalance the water chemistry and then submit a water sample to the regional health authority.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Written plans/procedures were not available for water quality incident responses.Please ensure written plans/procedures are established and maintained for water quality incident responses.
  19. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Written plans/procedures were not available for water quality incident responses.Please ensure written plans/procedures are established and maintained for water quality incident responses.
  20. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water results are unsatisfactory:- HPC: 1880 cfu/mLPool operator stated that boiler is currently down, and Pool is currently not open for use by the public. Once boiler is repaired, shock the pool, rebalance the water chemistry and then submit a water sample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Written plans/procedures were not available for water quality incident responses.Please ensure written plans/procedures are established and maintained for water quality incident responses.
  21. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water results are unsatisfactory:- HPC >57,000 cfu/mLUnsatisfactory laboratory result received, collection date August 28, 2024, HPC: 130 CFU/ml Ensure:1) All water parameters are balanced and maintained.2) A resample is submitted as soon as possible after treatment.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Written plans/procedures were not available for water quality incident responses.Please ensure written plans/procedures are established and maintained for water quality incident responses.
  22. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water results are unsatisfactory:- HPC >57,000 cfu/mL Ensure:1) All water parameters are balanced and maintained.2) A resample is submitted as soon as possible after treatment.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Written plans/procedures were not available for water quality incident responses.Please ensure written plans/procedures are established and maintained for water quality incident responses.
  23. Monitoring Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water results are unsatisfactory:- HPC >57,000 cfu/mL Ensure:1) All water parameters are balanced and maintained.2) A resample is submitted as soon as possible after treatment.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Written plans/procedures were not available for water quality incident responses.Please ensure written plans/procedures are established and maintained for water quality incident responses.
  24. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water results are unsatisfactory:- HPC 720 cfu/mL Ensure all water parameters is balanced and maintained and; samples are submitted as soon as possible.
  25. Risk Management Inspection

    0 infractions

  26. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water sample is only being submitted every 2 weeks. Please ensure pool samples are submitted weekly.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water results are unsatisfactory:- HPC 2460 cfu/mL Ensure all water parameters is balanced and maintained and; samples are submitted as soon as possible.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The rope was not attached to lifesaving throw ring.Ensure the lifesaving throw ring is always attached to a rope of a length greater than half of the width of the pool. It is design to be readily available in case of emergency.
  27. Risk Management Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water sample is only being submitted every 2 weeks. Please ensure pool samples are submitted weekly.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH is noted at "HI".Please adjust the pH and ensure the pH is maintained between 6.8 and 7.6.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The rope was not attached to lifesaving throw ring.Ensure the lifesaving throw ring is always attached to a rope of a length greater than half of the width of the pool. It is design to be readily available in case of emergency.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. The following area requires cleaning:-The pool basin 1. Please clean the indicated area.
  28. Risk Management Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water sample is only being submitted every 2 weeks. Please ensure pool samples are submitted weekly.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH is noted at "HI".Please adjust the pH and ensure the pH is maintained between 6.8 and 7.6.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. The following area requires cleaning:-The pool basin 1. Please clean the indicated area.
  29. Monitoring Inspection

    6 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water sample is only being submitted every 2 weeks. Please ensure pool samples are submitted weekly.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH is noted at "HI".Please adjust the pH and ensure the pH is maintained between 6.8 and 7.6.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The water level in the pool is not high enough to each the skimmers and float the weirINCREASE POOL VOLUME TO ACTIVATE SKIMMER FILTRERS
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • As indicated by staff, the gasket in the pool sand filter is in disrepair/malfunctioning causing the pool water level to drop. Please repair the pool gasket.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The pool water level is approximately half a foot below the waterline potentially affecting the disinfection rate, circulation rate, and pool user safety. Please ensure the water level is maintained as per pool operational design. The site voluntarily closed the pool.**Please keep the pool closed until the issue is repaired and the water level can be maintained as per operational design.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. The following area requires cleaning:-The pool basin 1. Please clean the indicated area.