The Vault Fitness - Cold Plunge 2 has been inspected 13 times by Alberta Health Services (Environmental Public Health) since July 13, 2026. The most recent inspection, on October 9, 2026, found no infractions.

6 of 13 inspections on record found no infractions at all. In the past 12 months there were 13 inspections with 18 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 16 times across 7 separate inspections, most recently on October 5, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on September 28, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded once on September 28, 2026. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

13 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on Oct. 2, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample collected on Sep. 23, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample result collected on 28/09/2026 [ID#: 26-EN272-E000782] was unsatisfactory: total coliforms present. Pool closure requested due to consecutive unsatisfactory sample results. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Air bubbles and crystallization and build up was observed in the tubing for the automated controller, including for ORP (chlorine). Furthermore, crystallization/build up was observed in the window of the ORP peristaltic pump.Corrective Action:Ensure automated controller is properly maintained to ensure bacteriologically and chemically safe water.
  3. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample collected on Sep. 23, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample result collected on 28/09/2026 [ID#: 26-EN272-E000782] was unsatisfactory: total coliforms present. Pool closure requested due to consecutive unsatisfactory sample results. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Air bubbles and crystallization and build up was observed in the tubing for the automated controller, including for ORP (chlorine). Furthermore, crystallization/build up was observed in the window of the ORP peristaltic pump.Corrective Action:Ensure automated controller is properly maintained to ensure bacteriologically and chemically safe water.
  4. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample collected on Sep. 23, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free chlorine was measured at 0.18 mg/L.Corrective Action:- Ensure free chlorine is maintained at 1.0 mg/L.- Alternatively, free chlorine can be maintained at greater than or equal to 0.5 mg/L if ORP is maintained at or higher than 700 mV.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The container for acid feeding the automated controller for pH was observed to be empty.Corrective Action:Ensure automated controller is properly maintained to ensure bacteriologically and chemically safe water.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Air bubbles and crystallization and build up was observed in the tubing for the automated controller, including for ORP (chlorine). Furthermore, crystallization/build up was observed in the window of the ORP peristaltic pump.Corrective Action:Ensure automated controller is properly maintained to ensure bacteriologically and chemically safe water.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Water testing records were reviewed. Insufficient water testing and record keeping was observed. Water testing and record keeping is inconsistent.Corrective Action:- Advised operator that when cold plunges are in use, water testing and record keeping must be maintained.- Operator noted that multiple staff will be trained for water testing, record keeping, and basic maintenance.
  5. Risk Management Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample collected on Sep. 23, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Air bubbles and crystallization and build up was observed in the tubing for the automated controller, including for ORP (chlorine). Furthermore, crystallization/build up was observed in the window of the ORP peristaltic pump.Corrective Action:Ensure automated controller is properly maintained to ensure bacteriologically and chemically safe water.
  6. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample collected on Sep. 23, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on Aug. 24, 2026, was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on Aug. 14, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on Aug. 14, 2026, was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.