World Mark - Indoor Whirlpool
91 Three Sisters Drive Canmore AB T1W 2X4 · Aquatic Facility
11 inspections
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Treat water to remove contamination. Resample.Whirlpool to close and remain closed until such time as a water sample is submitted that is confirmed to be satisfactory.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a plate count of 5,400 cfu/ml. Treat water to remove contamination. Resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Treat water to remove contamination. Resample.Whirlpool to close and remain closed until such time as a water sample is submitted that is confirmed to be satisfactory.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a plate count of 5,400 cfu/ml. Treat water to remove contamination. Resample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Controller readings are still not consistent with manual tests. Free chlorine was measured as 3.16ppm, controller was reading 9.99ppm.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Treat water to remove contamination. Resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a plate count of 5,400 cfu/ml. Treat water to remove contamination. Resample.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Some of the metal rings are missing around the inlets and outlets. This could be a hazard if the exposed cut tile edges are sharp and/or may leave a gap large enough for a child to get a hand stuck in. Replace the missing rings.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Treat water to remove contamination. Resample.Whirlpool to close and remain closed until such time as a water sample is submitted that is confirmed to be satisfactory.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a plate count of 5,400 cfu/ml. Treat water to remove contamination. Resample.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH was measured as 8.13, to be kept between 6.8 and 7.6.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Controller readings are not consistent with manual tests. Free chlorine was measured as over 8ppm (est. at 10-11ppm), controller was reading 5ppm. pH was measured as 8.13, controller was reading 7.3.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Two of the screws for one of the main drains were rusty. Replace screws (same type as required as per manufacturer of drain cover) with ones that are not rusty.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample received by the lab today was not tested as there was no date or time of collection on the form. Resample to be submitted.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Some of the metal rings are missing around the inlets and outlets. This could be a hazard if the exposed cut tile edges are sharp and/or may leave a gap large enough for a child to get a hand stuck in. Replace the missing rings.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- March 6/25 water sample had Pseudomonas isolated. Close whirlpool until a Pseudomonas disinfection is done. Resample.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Some of the metal rings are missing around the inlets and outlets. This could be a hazard if the exposed cut tile edges are sharp and/or may leave a gap large enough for a child to get a hand stuck in. Replace the missing rings.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Some of the metal rings are missing around the inlets and outlets. This could be a hazard if the exposed cut tile edges are sharp and/or may leave a gap large enough for a child to get a hand stuck in. Replace the missing rings.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Monitoring Inspection
6 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample was not submitted the week of November 11-14, 2024. A water sample is to be submitted each week (unless the pool is closed for maintenance).
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine level in the whirlpool water was measured as >3.6ppm and there was a strong chloramine smell in the indoor pool area. Keep the combined chlorine level as low as possible.Corrected during inspection; whirlpool was drained during inspection to fill with new water.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Both the skimmer and main drain lines are fully open. Are to maximize flow through the skimmers.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The two main drains only have 3 screws each. The installation instructions for the cover state that 4 screws are required. Ensure a fourth screw is placed in each cover.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Some of the metal rings are missing around the inlets and outlets. This could be a hazard if the exposed cut tile edges are sharp and/or may leave a gap large enough for a child to get a hand stuck in. Replace the missing rings.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
6 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken this week (Aug. 29th) was not tested as the requisition form stated the sample was taken on Oct. 29th. Resample to be submitted.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 36ppm.Raise the alkalinity of this pool to at least 60ppm to ensure it has sufficient buffering capacity.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine of this pool was recorded at 2.60ppm at the time of inspection.Reduce combined chlorine levels in this pool to be as low as possible. Recommend taking additional measures to ensure guests to the hot tub are showering with soap prior to entry.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the circulation line of this basin was not operational at the time of inspection. Repair flow meter to ensure that the flow rate of this pool can be recorded.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
5 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 36ppm.Raise the alkalinity of this pool to at least 60ppm to ensure it has sufficient buffering capacity.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine of this pool was recorded at 2.60ppm at the time of inspection.Reduce combined chlorine levels in this pool to be as low as possible. Recommend taking additional measures to ensure guests to the hot tub are showering with soap prior to entry.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the circulation line of this basin was not operational at the time of inspection. Repair flow meter to ensure that the flow rate of this pool can be recorded.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?