World Mark - Outdoor Whirlpool
91 Three Sisters Drive Canmore AB T1W 2X4 · Aquatic Facility
25 inspections
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample taken on May 19, 2026 had total coliforms present. Treat water to remove contamination. Resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on January 5, 2026 had a heterotrophic plate count of 310cfu/ml. Treat water to remove contamination. Resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Dec.29/25; Sample had HPC of 670cfu/ml. Treat and resample
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on October 9, 2025 had Pseudomonas present and total coliforms isolated.Close whirlpool until a Pseudomonas disinfection is done. Submit a resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on October 9, 2025 had a plate count of over 57,000 cfu/ml. Treat whirlpool to remove contamination. Submit a resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Dec.29/25; Sample had HPC of 670cfu/ml. Treat and resample
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on October 9, 2025 had Pseudomonas present and total coliforms isolated.Close whirlpool until a Pseudomonas disinfection is done. Submit a resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on October 9, 2025 had a plate count of over 57,000 cfu/ml. Treat whirlpool to remove contamination. Submit a resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Risk Management Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Pseudomonas disinfection to be done and resample taken. Whirlpool to be closed and kept closed until new water sample submitted whose results are confirmed to be satisfactory.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken September 4th, 2025, had an HPC of 870 CFU/ml. Whirlpool water to be treated and resample taken.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a heterotrophic plate count of 10,000 cfu/ml. Treat water to remove contamination. Resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Pseudomonas disinfection to be done and resample taken. Whirlpool to be closed and kept closed until new water sample submitted whose results are confirmed to be satisfactory.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken September 4th, 2025, had an HPC of 870 CFU/ml. Whirlpool water to be treated and resample taken.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a heterotrophic plate count of 10,000 cfu/ml. Treat water to remove contamination. Resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Pseudomonas disinfection to be done.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken September 4th, 2025, had an HPC of 870 CFU/ml. Whirlpool water to be treated and resample taken.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a heterotrophic plate count of 10,000 cfu/ml. Treat water to remove contamination. Resample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated maintenance system is not reading consistently with measured chlorine and pH readings. To be repaired or replaced. Was advised it was fixed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
7 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- September 11, 2025 water sample had Pseudomonas isolated. Pseudomonas disinfection to be done and resample taken. Whirlpool to be closed and kept closed until new water sample submitted whose results are confirmed to be satisfactory.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken September 4th, 2025, had an HPC of 870 CFU/ml. Whirlpool water to be treated and resample taken.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 11, 2025 water sample had a heterotrophic plate count of 10,000 cfu/ml. Treat water to remove contamination. Resample.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free chlorine was measured as only 1.04ppm. Free chlorine level to be kept at a minimum of 2ppm.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured as 41ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pH was measured as 7.4ppm, the controller was reading 7.15ppm. Calibrate controller.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is some cracking between the tiles at the bottom of the whirlpool. The grout needs to be redone in this area to fill the crack.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken September 4th, 2025, had an HPC of 870 CFU/ml. Whirlpool water to be treated and resample taken.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated maintenance system is not reading consistently with measured chlorine and pH readings. To be repaired or replaced. Was advised it was fixed.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken August 7th, 2025, had an HPC of 130 CFU/ml. Whirlpool water to be treated and resample taken.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated maintenance system is not reading consistently with measured chlorine and pH readings. To be repaired or replaced. Was advised it was fixed.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample taken on July 24, 2025 had Pseudomonas isolated. Whirlpool to be closed until a Pseudomonas disinfection is done. Resample to be submitted.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample taken on July 24, 2025 had a heterotrophic plate count of over 57,000 cfu/ml. Treat water to remove contamination. Resample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated maintenance system is not reading consistently with measured chlorine and pH readings. To be repaired or replaced. Was advised it was fixed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- January 9, 2025 water sample had total coliforms present and Pseudomonas was isolated. Whirlpool to be closed until a Pseudomonas disinfection is done. Resample to be submitted.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- January 9, 2025 water sample had a plate count of over 57,000 cfu/ml. Whirlpool to be treated to remove contamination. Resample to be submitted.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated maintenance system is not reading consistently with measured chlorine and pH readings. To be repaired or replaced. Was advised company has already been contacted and have been waiting for a new part. Controller needs to be working properly so may need to replace it if new part is not coming soon and/or if can't maintain proper water chemistry or quality.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated maintenance system is not reading consistently with measured chlorine and pH readings. To be repaired or replaced. Was advised company has already been contacted and have been waiting for a new part. Controller needs to be working properly so may need to replace it if new part is not coming soon and/or if can't maintain proper water chemistry or quality.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
5 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 35ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated maintenance system is not reading consistently with measured chlorine and pH readings. To be repaired or replaced. Was advised company has already been contacted.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Both the main drain and skimmer lines were fully open. Are to be pulling more from the skimmer lines than the main drain.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day and this is recorded in pool log, along with a visual inspection of main drain covers for any damage or defects.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Some of the skimmers are full of leaves. Ensure skimmer baskets are cleaned often.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
5 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample taken on November 7, 2024 was not tested as there was no identification number on the bottle. Resample to be submitted.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
6 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken Oct. 17, 2024 had total coliforms present and Pseudomonas isolated. Close whirlpool until a Pseudomonas disinfection is done; resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken Oct 17, 2024 had a plate count of over 57,000 cfu/ml. Treat whirlpool water to remove contamination.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
5 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1) Water sample from September 12th, 2024, had an HPC of 1,880 CFU/ml. - Operators were informed to treat and re-sample.2) Water sample from September 16th, 2024, had an HPC of 740 CFU/ml. - Operators were informed to treat and re-sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
5 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from September 12th, 2024, had an HPC of 1,880 CFU/ml. - Operators were informed to treat and re-sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
5 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken this week (Aug. 29th) was not tested as the requisition form stated the sample was taken on Oct. 29th). Resample to be submitted.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
4 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
5 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Anti-entrapment plan did not include the information for the jet system, only for the recirculation system. Please complete anti-entrapment plan fully and provide for review.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
6 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- July 13/23 water sample had Pseudomonas isolated. Water to be treated to remove contamination and resample submitted this Thursday.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of this pool was recorded at 27ppm. Raise the total alkalinity to at least 60ppm to ensure the pool has sufficient buffering capacity.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The water clarity and condition of the main drains were not being recorded daily. Ensure water clarity is checked at least once per day, along with a visual inspection of main drain covers for any damage or defects.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The secondary anti-entrapment mechanisms for this pool were not being tested on a regular basis. Ensure that the vacuum release mechanism equip to each pump are being tested per manufacturer's specifications, or at least once per month.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The flow meter for the jet pump of this pool was not reading accurately at the time of inspection. Ensure flow meter is working properly.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Anti-entrapment plan could not be located. If can't find, will need to do a new written anti-entrapment plan.*Ongoing violation. Send current anti-entrapment plan for review. *
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?