World Waterpark - System 5 (Single Hot Tub - West)
1784 - 8882 170 Street NW Edmonton AB T5T 4M2 · Aquatic Facility
6 inspections
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- the sample 25EN-148E00628 submitted on May 28, 2025, was unsatisfactory: Pseudomonas aeruginosa was isolated.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
3 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine residual was 1.82 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There was a discrepancy between the manual reading for pH 6.86, and the automated controller reading for pH 7.31.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The pool basin was in disrepair near one of the main drains.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine residual was 1.82 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There was a discrepancy between the manual reading for pH 6.86, and the automated controller reading for pH 7.31.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?