14810 51 Avenue NW - Whirlpool

14810 51 Avenue NW Edmonton AB T6H 5G5 · Aquatic Facility

Inspection summary

14810 51 Avenue NW - Whirlpool has been inspected 10 times by Alberta Health Services (Environmental Public Health) since November 29, 2023. The most recent inspection, on September 24, 2026, recorded 2 infractions.

2 of 10 inspections on record found no infractions at all. In the past 12 months there was 1 inspection with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Chemicals and toxic substances and Food temperature control.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 9 times across 7 separate inspections, most recently on February 26, 2025. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 4 times across 3 separate inspections, most recently on September 24, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded once on September 24, 2026. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded once on November 29, 2023. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

10 inspections

  1. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The free chlorine was 1.52 ppm, with ORP 690 mV and the water temperature over 30C. Ensure that the free chlorine is maintained at or above 2 ppm (if ORP below 700 mV) in the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Cleaning of the skimmer was required. It was addressed during the inspection.
  2. Demand Inspection

    0 infractions

  3. Risk Management Inspection

    0 infractions

  4. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was 38 ppm. Please ensure that it is maintained between 60 and 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the manual pH reading 6.69 and the automated controller reading pH 7.2. Please address.
  5. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • With flow rate 65 gpm, the rate of filtration was 13.27 gpm/ft2. To ensure that the filtration rate does not exceed maximum allowed 12.5 gpm/ft2, the flow rate should not exceed 61 gpm. Note: according to the provided information, filter flow rate should be 50 gpm (see notes).
  6. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 24EN-250E00370 submitted on September 6, 2024, was unsatisfactory: Total coliforms present.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • With flow rate 65 gpm, the rate of filtration was 13.27 gpm/ft2. To ensure that the filtration rate does not exceed maximum allowed 12.5 gpm/ft2, the flow rate should not exceed 61 gpm. Note: according to the provided information, filter flow rate should be 50 gpm (see notes).
  7. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • With flow rate 65 gpm, the rate of filtration was 13.27 gpm/ft2. To ensure that the filtration rate does not exceed maximum allowed 12.5 gpm/ft2, the flow rate should not exceed 61 gpm. Note: according to the provided information, filter flow rate should be 50 gpm (see notes).
  8. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 9 Aug 2024 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • With flow rate 65 gpm, the rate of filtration was 13.27 gpm/ft2. To ensure that the filtration rate does not exceed maximum allowed 12.5 gpm/ft2, the flow rate should not exceed 61 gpm. Note: according to the provided information, filter flow rate should be 50 gpm (see notes).
  9. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • With flow rate 65 gpm, the rate of filtration was 13.27 gpm/ft2. To ensure that the filtration rate does not exceed maximum allowed 12.5 gpm/ft2, the flow rate should not exceed 61 gpm. Note: according to the provided information, filter flow rate should be 50 gpm (see notes).
  10. Monitoring Inspection

    4 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • 1. Free Chlorine was 0.38 ppm (corrected to 2.8 ppm during the inspection). Ensure that free chlorine is maintained above 2 ppm.2. The pH was 6.5 (corrected to 6.91 during the inspection). Ensure that pH is maintained between 6.8 and 7.6.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was 10 ppm (corrected to 58 ppm during the inspection). Ensure that total alkalinity is maintained between 60 and 180 ppm.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • There were no records of testing the secondary layer of anti-entrapment protection device available. The testing was conducted during the inspection. Ensure that the device is tested as per manufacturer's instructions, and the results of testing are recorded.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • * Rate of filtration for the filtration system could not be determined - a new filter was installed, and no information regarding a filtration area was provided.* A new disinfection system was installed (Pulsar Infinity pack system) but no information regarding the alteration was submitted to AHS.