Baymont Inn & Suites - Swimming Pool
4311 49 Avenue Red Deer AB T4N 5Y7 · Aquatic Facility
Inspection summary
Baymont Inn & Suites - Swimming Pool has been inspected 30 times by Alberta Health Services (Environmental Public Health) since January 9, 2024. The most recent inspection, on June 22, 2026, found no infractions.
13 of 30 inspections on record found no infractions at all. In the past 12 months there were 7 inspections with 3 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 11 times across 11 separate inspections, most recently on June 15, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 2 times on January 9, 2024. For example:
Is the chemical quality of the water in this pool satisfactory (Critical)?
Food safety training and certificationLower risk
Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.
Recorded 8 times across 8 separate inspections, most recently on June 17, 2024. For example:
Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
30 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample result:Total coliforms - ABSENTHPC - 200 cfu/100mL *unsatisfactorySample collected June 10, 2026 by Helbert.The pool was closed for the day (Monday, June 15, 2026) for routine weekly cleaning. The facility has experienced maximum bather loads for more than three consecutive weeks. Pool Operator Helbert will ensure the free chlorine concentration is raised to 10 ppm and maintained for one full turnover period, prior rebalancing the pool and taking another sample and reopening the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Unsatisfactory water sample result:Total coliforms – Present *unsatisfactoryHPC < 10 cfu/100mL ---Sample collected March 25, 2026 by Helbert.Pool operators will complete cleaning of the pool and perform shocking and backwashing on Monday, March 30, prior to resampling on Wednesday, April 1.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample result:Total coliforms - ABSENTHPC - 160 cfu/100mL *unsatisfactorySample collected March 4 2026 by Helbert.---Sample was taken when the hotel was busy during a hockey tournament.The operator has since completed cleaning and shock treatment of the pool and will resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Unsatisfactory bacteriological water sample taken June 18:Total Coliforms - PRESENTContacted operator to shock chlorinate.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample result:Total coliforms - ABSENTHPC - 3110 cfu/100mL *unsatisfactorySample collected Feb 26, 2025.ACTION:Please shock chlorinate the pool using the steps outlined in the document below:https://www.albertahealthservices.ca/assets/wf/eph/wf-eph-interpret-microbiological-sample-results-pools.pdfThis doucment was emailed to operator as well.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample received.Total coliforms - ABSENTHPC - 140 CFU/100mLSample collected Oct 9.Please shock chlorinate the pool, return to normal operational chemistry, and submit a new sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample received.Total coliforms - ABSENTHPC - 230 CFU/100mLSample collected Sept 18.Please shock the pool and submit a resample after returning to normal operational chemistry.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample received.Total coliforms - ABSENTHPC - 2,200 CFU/100mLSample collected on Aug 21.ACTION: Please shock chlorinate the pool and resample after returning to normal operating chemistry.https://www.albertahealthservices.ca/assets/wf/eph/wf-eph-interpret-microbiological-sample-results-pools.pdf
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- June 17, 2024The operator mentioned during an email on June 11, 2024, that anti-entrapment information was already sent to inspector Nicole, and the facility is waiting for an assessment from the inspector.  March 21, 2024Additional information is required to complete anti-entrapment review.Please provide requested information.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The bacteriological water sample collected on June 5, 2024, has a heterotrophic plate count of 240 CFU/mL. Please ensure that the pool water is resampled.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC > 1020 CFU/mL
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample result for sample collected / submitted on May 01 2024 with HPC 3150.T C Absent I called Helbert and informed him of the result. Helbert stated that they were very busy last weekend and the fc fell below 1 ppm.A shock treatment was done with a new product.The fc was then raised to 3 ppm.This morning the f c was at 1.19 ppm.Helbert will shock the pool again and also submit another sample. Monday is maintenance day so the pool is closed for the day.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Demand Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Missing information/supporting documents were not attached to the anti-entrapment plan; therefore, a complete review could not occur.Please provide requested information.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The free available chlorine level were measured at 0.38/0.47/0.3 ppm with pH at 7.5 and ORP at 381mV.- Ensure the FAC is maintain 1ppm or higher, OR higher than 0.5 ppm with ORP higher than 700mV, OR higher than 0.3ppm with pH less than 7.3 and ORP higher than 770mV
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity level were measured at 188ppm and over range. - Ensure TA level is between 60 - 180ppm
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
Nearby inspected facilities
- Baymont Inn & Suites - Whirlpool
4311 49 Avenue Red Deer AB T4N 5Y7
15 inspections
- Baymont Inn & Suites - Pool Common Areas
4311 49 Avenue Red Deer AB T4N 5Y7
6 inspections
- Food Factory Kitchen & Catering
4311 49 Avenue Red Deer AB T4N 5Y7
15 inspections
- Phil's Restaurant
4312 49 Avenue Red Deer AB T4N 3W6
10 inspections
- Electrolysis & Esthetics by Gillian
4407 48 Avenue Red Deer AB T4N 2S3
2 inspections
- Sierra Grande - Pool Common Area
4805 45 Street Red Deer AB T4B 7A9
4 inspections
- Sierra Grande - Swimming Pool
4805 45 Street Red Deer AB T4B 7A9
12 inspections
- Sierra Grande - Whirlpool
4805 45 Street Red Deer AB T4B 7A9
6 inspections