Blooming Beauty
206 - 1039 17 Avenue SW Calgary AB T2T 0A9 · Personal Services
6 inspections
- Demand Inspection
1 infraction
- 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
- A water machine was located in the reprocessing area. Removed.
- 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
- Monitoring Inspection
3 infractions
- 20. Is reusable equipment disinfected properly?
- For TM Beauty:Using HLD 5 to disinfect reusable tools. Solution is being reused, but not tested and not maintaining a reuse log.If reusing HLD 5, for each day of reuse, solution must be tested, verified to be acceptable concentration, and a log maintained.
- 20. Is reusable equipment disinfected properly?
- For TM Beauty:The incorrect test strips were available for HLD 5. CS20 test strips, which were also expired, were available.Either discard HLD 5 solution daily or obtain correct test strips.
- 20. Is reusable equipment disinfected properly?
- Operator stated that reusable tools are reprocessed by: placing into CS20 for 20 minutes, then rinsing, then drying.Proper reprocessing procedure for CS20:- Clean tools with soap and water- Rinse tools with fresh water- Fully dry tools- Fully submerge in CS20 for 20 minutes- Rinse with fresh water- Dry
- 20. Is reusable equipment disinfected properly?
- Monitoring Inspection
3 infractions
- 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
- There were no paper towels available at the hand wash sink.Ensure that paper towels are always available at hand wash sinks.
- 20. Is reusable equipment disinfected properly?
- CS20 solution had expired November 2, 2024. Obtain new CS20 that is within the expiration date.
- 20. Is reusable equipment disinfected properly?
- Operator stated that reusable tools are reprocessed by: placing into CS20 for 20 minutes, then rinsing, then drying.Proper reprocessing procedure for CS20:- Clean tools with soap and water- Rinse tools with fresh water- Fully dry tools- Fully submerge in CS20 for 20 minutes- Rinse with fresh water- Dry
- 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
- Demand Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Initial Inspection
4 infractions
- 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
- 1) Paper towel was sitting directly on the counter by the handwash sink.-install a paper towel dispenser so the paper towel is not contaminated by the sink surface.
- 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
- 1) Nail prep solution was from Japan and didn't have an English label nor did it have a DIN.-obtain a product with a DIN
- 20. Is reusable equipment disinfected properly?
- 1) There were no test strips available for disinfectant.-obtain test strips to measure disinfectant concentration2) No logs were available for disinfectant monitoring.
- 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
- A linen cloth/liner was used in the work station. -remove the cloth and ensure all surfaces are smooth, durable, non-absorbent and easily washable.
- 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?