Central Memorial Park - Walkway Fountain
1221 2 Street SW Calgary AB T2R 0W5 · Aquatic Facility
Inspection summary
Central Memorial Park - Walkway Fountain has been inspected 9 times by Alberta Health Services (Environmental Public Health) since June 6, 2024. The most recent inspection, on September 14, 2026, recorded 1 infraction.
2 of 9 inspections on record found no infractions at all. In the past 12 months there were 5 inspections with 8 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Chemicals and toxic substances and Food temperature control.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 7 times across 6 separate inspections, most recently on September 14, 2026. For example:
Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 3 times across 3 separate inspections, most recently on July 31, 2026. For example:
Is the chemical quality of the water in this pool satisfactory (Critical)?
Food temperature controlHigher risk
Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.
Recorded once on June 6, 2024. For example:
Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
9 inspections
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- In discussion with the facility manager, it was discovered that the flow meter is between the two filters, and not after. This would not represent the total flow of the water in the system.-Operator to install new flow meter in a location that is representative of the flow rate of the whole system
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on August 24/26 had HPC of 220 cfu/ml.- Submit a resample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- In discussion with the facility manager, it was discovered that the flow meter is between the two filters, and not after. This would not represent the total flow of the water in the system.-Operator to install new flow meter in a location that is representative of the flow rate of the whole system
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- In discussion with the facility manager, it was discovered that the flow meter is between the two filters, and not after. This would not represent the total flow of the water in the system.-Operator to install new flow meter in a location that is representative of the flow rate of the whole system
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH measured at 8.17-Maintain pH between 6.8 - 7.6
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Manual pH reading on both inspector and operator's test kits was >8.0. Automated system reading was 7.14. Also observed automated system reader fluctuate from around 7.6 down to 7.1 in around 20 minutes while reviewing items in the mechanical room.-Have the system serviced so that the readings are consistent and the chemistry does not fluctuate wildly
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- 1) Free chlorine tested at 1.78 mg/L.-Maintain free chlorine at 2 mg/L or higher2) pH tested at 7.68.-Maintain pH between 6.8 and 7.6Operator provided chemistry test kit readings showing fCL 6.00 and pH 7.39 after inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The bob in the flow meter was stuck at the bottom. Staff had recorded this bottom number multiple days in a row.-Operator freed the bob during the inspection
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH was tested multiple times (8.14, 8.03, and 8.13) and was too high. The pH must be kept between 6.8 and 7.6. Please decrease the pH.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Unable to determine turnover period as volume is not available.-Report the pool volume, ensure turnover is <2 hours
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- One block on the east spray pad was broken, and a temporary block was secured in place with wooden boards.-Operator already has plans to insert a block of appropriate size, install when possible
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Nearby inspected facilities
- Calgary Pop-Up Care Village
1221 2 Street SW Calgary AB T2R 0W5
1 inspection
- Central Memorial Park - Common Area
1221 2 Street SW Calgary AB T2R 0W5
6 inspections
- Fairfield Inn & Suites by Marriott
239 12 Avenue SW Calgary AB T2R 1H7
1 inspection
- Native Tongues Taqueria
1 - 235 12 Avenue SW Calgary AB T2R 0H6
5 inspections
- Native Tongues Taqueria - Events
1 - 235 12 Avenue SW Calgary AB T2R 0H6
1 inspection
- Birdie
100D - 227 11 Avenue SW Calgary AB T2R 1R9
4 inspections
- LTL Culinary
130 - 227 11 Avenue SW Calgary AB T2R 1R9
3 inspections
- Joyfish
100E - 227 11 Avenue SW Calgary AB T2R 1R9
7 inspections