Comfort Inn & Suites Airdrie - Swimming Pool
133 Sierra Springs Drive SE Airdrie AB T4B 3G7 · Aquatic Facility
3 inspections
- Demand Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on June 24 had a HPC count of 230 CFU/mL. Operator informed to submit re-sample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Hair noted in skimmer baskets.COMPLETE THE FOLLOWING:1. Please ensure baskets are checked and cleaned more often to ensure adequate circulation of the pool water.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. Observed chipped basin material to the left of the south drain cover.COMPLETE THE FOLLOWING:1. Repair the area noted above.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. The alkalinity reagents expired in August and December 2024.2. There was no column for water clarity in the daily log sheet. COMPLETE THE FOLLOWING:1. Please purchase new reagents. 2. Include a column for water clarity in the daily log sheets.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Hair noted in skimmer baskets.COMPLETE THE FOLLOWING:1. Please ensure baskets are checked and cleaned more often to ensure adequate circulation of the pool water.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. Observed chipped basin material to the left of the south drain cover.COMPLETE THE FOLLOWING:1. Repair the area noted above.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. The alkalinity reagents expired in August and December 2024.2. There was no column for water clarity in the daily log sheet. COMPLETE THE FOLLOWING:1. Please purchase new reagents. 2. Include a column for water clarity in the daily log sheets.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Initial Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The calculated turnover rate in hours was 5.5 hours based on a pool volume of 22,418 USG and a flow rate of 68 GPM. Pools constructed after 2006 must achieve a turnover rate within 4 hours. Please increase the turnover rate so that it does not exceed 4 hours.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?