Comfort Inn & Suites Airdrie - Swimming Pool

133 Sierra Springs Drive SE Airdrie AB T4B 3G7 · Aquatic Facility

3 inspections

  1. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on June 24 had a HPC count of 230 CFU/mL. Operator informed to submit re-sample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. Hair noted in skimmer baskets.COMPLETE THE FOLLOWING:1. Please ensure baskets are checked and cleaned more often to ensure adequate circulation of the pool water.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. Observed chipped basin material to the left of the south drain cover.COMPLETE THE FOLLOWING:1. Repair the area noted above.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. The alkalinity reagents expired in August and December 2024.2. There was no column for water clarity in the daily log sheet. COMPLETE THE FOLLOWING:1. Please purchase new reagents. 2. Include a column for water clarity in the daily log sheets.
  2. Monitoring Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. Hair noted in skimmer baskets.COMPLETE THE FOLLOWING:1. Please ensure baskets are checked and cleaned more often to ensure adequate circulation of the pool water.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. Observed chipped basin material to the left of the south drain cover.COMPLETE THE FOLLOWING:1. Repair the area noted above.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. The alkalinity reagents expired in August and December 2024.2. There was no column for water clarity in the daily log sheet. COMPLETE THE FOLLOWING:1. Please purchase new reagents. 2. Include a column for water clarity in the daily log sheets.
  3. Initial Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The calculated turnover rate in hours was 5.5 hours based on a pool volume of 22,418 USG and a flow rate of 68 GPM. Pools constructed after 2006 must achieve a turnover rate within 4 hours. Please increase the turnover rate so that it does not exceed 4 hours.