Comfort Inn & Suites - Whirlpool
2369 Banff Trail NW Calgary AB T2M 4L2 · Aquatic Facility
15 inspections
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool basin was observed to have excessive staining and pitting. Operator advised of remediation efforts to commence later this year, which would include resurfacing the basin with tile.Requirement: All aspects of the pool must be maintained in clean, sanitary condition and must be in good repair.** Ensure that tile colour is light so that the bottom of the basin is easily visible
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Monitoring Inspection
3 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine calculated at 2.54 mg/L.-Ensure combined chlorines are maintained as low as possible
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The main drain was observed to be missing one of 16 screws.-Obtain a screw that complies with the manufacturer's installation instructions and apply immediately
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Whirlpool basin was observed to have excessive staining and pitting. Operator advised of remediation efforts to commence later this year, which would include resurfacing the basin with tile.Requirement: All aspects of the pool must be maintained in clean, sanitary condition and must be in good repair.** Ensure that tile colour is light so that the bottom of the basin is easily visible
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample not tested, received by lab on weekend.-Resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated controller for the whirlpool needs to recalibrate. Controller was displaying a free chlorine level of 3.4 compared to the measured chlorine level of 2.77 during the inspection.Please recalibrate the automated controller so the displayed chlorine level is accurate.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- A clock was not visible around the whirlpool. patrons need to be able to monitor their time in a whirlpool for safety purposes. Operator reinstalled a working clock during the inspection.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The facility had new pumps for the whirlpool, but the anti-entrapment plans were not updated to include the updated pump details.Please update the anti-entrapment plans to reflect the new jet and recirculation pumps.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- 1. The water sample collected on March 25 2025 resulted in the isolation of Pseudomonas.-treat and resample.2. The water sample collected on April 3 2025 resulted in the isolation of Pseudomonas- Closure Order issued.- Please treat the whirlpool, backwash, drain, scrub, fill, balance, and resample. Closure Order can be lifted once a satisfactory water sample result is obtained
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on March 25 2025 resulted in the isolation of Pseudomonas.-treat and resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Aug 30 resulted in the isolation of Pseudomonas.-treat and resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on Aug 23 was no processed as there was no identification number on the bottle.ID #: 24ES-236E00130
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free chlorine residual was measured at 0.50ppm. FCL must be maintained at a minimum of 2.00ppm in a pool maintained above 30C
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated feeders are not operating as calibrated. Repair automated feeders so that chemicals are consistent.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Accession #: WC-24-0011635Result: Pseudomonas IsolatedTreat and resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Accession #: WC-24-0011642Result: HPC of 120 CFU/mLTreat and resample
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on November 01, 2023, was not processed due to the identification number sticker not being attached to the water sample bottle.REQUIREMENT: Submit another water sample and ensure the identification number sticker is attached to the bottle.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?