Deerfoot Inn & Casino - Center Whirlpool
1000 - 11500 35 Street SE Calgary AB T2Z 3W4 · Aquatic Facility
7 inspections
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The flow metre for the recirculation pump read 45 GPM. The calculated minimum flow rate for the whirlpool is 67 GPM. **April 24, 2026: flow metre read 50 GPM and calculated turnover rate was 20 minutes. COMPLETE THE FOLLOWING:1. The operational flow rate for the recirculation pump needs to be increased to at least 67 GPM to achieve a recirculation rate of 15 minutes. Ensure all pool equipment is in good working condition. A drop in flow rate may indicate the filters need to be backwashed/maintenance required, skimmers need cleaning, and/or pump issues.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The jet pump flow metre was not operational.2. The Operators stated the main drain valve is opened at 50%. 3. The flow metre for the recirculation pump read 45 GPM. The calculated minimum flow rate for the whirlpool is 67 GPM. COMPLETE THE FOLLOWING:1. Replace the jet pump flow metre.2. Please adjust the main drain valve so that it is opened no more than 30% to increase flow of water through the skimmers, as the top portion of the pool water contains greater amounts of contaminants than the bottom.3. The operational flow rate for the recirculation pump needs to be increased to at least 67 GPM to achieve a recirculation rate of 15 minutes. Ensure all pool equipment is in good working condition. A drop in flow rate may indicate the filters need to be backwashed/maintenance required, skimmers need cleaning, and/or pump issues.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample collected on Nov 6, 2025 was not processed since it did not have a collection time.-resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample was rejected due to incorrect collection date. The Date Time of sample collection is LATER than the Date Time of receipt.Resampling advised.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Monitoring Inspection
0 infractions