Eau Claire Athletic Club - Main Pool
101 3 Street SW Calgary AB T2P 4G6 · Aquatic Facility
Inspection summary
Eau Claire Athletic Club - Main Pool has been inspected 14 times by Alberta Health Services (Environmental Public Health) since July 2, 2025. The most recent inspection, on October 2, 2026, recorded 1 infraction.
6 of 14 inspections on record found no infractions at all. In the past 12 months there were 5 inspections with 3 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 8 times across 7 separate inspections, most recently on October 2, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
Food safety training and certificationLower risk
Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.
Recorded 3 times across 3 separate inspections, most recently on August 5, 2025. For example:
Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
14 inspections
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (26ES-273E00010) collected on September 30, 2026 was not processed due to non-urgent sample being received during the weekend/holiday without approval.Please resubmit the sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (26ES-049E00733) collected on February 18th, 2026, was rejected by the lab as the time of collection was not recorded on the requisition form. Please resample as soon as possible.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (26ES-029E00043) collected on January 28th, 2026, for the main pool came back unsatisfactory as the HPC was slightly elevated (110CFU/mL). The maximum acceptable concentration is 100CFU/mL. Please resample the main pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (25ES-258E00048) collected on September 15th, 2025, was rejected by the lab as the time of collection was not recorded.Please submit a new sample for the main pool as soon as possible.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Initial Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Minor adjustments to the anti-entrapment plan are needed. See opening comments for specific items.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- A discrepancy was observed between the chlorine reading on automated controller and manual testing. Manual test (FC): 3.55ppm Automated test: 2.33mg/LPlease ensure the automated controller is calibrated properly and consistent with manual testing.Update: (2025-07-16). The manual test reading for chlorine was measured at 4.72 ppm and was not consistent with the automated reading of 5.59 ppm. Please calibrate the probes to ensure that the manual reading is consistent with the automated reading.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Concerns over the anti-entrapment plan (needs updating to reflect the following: correct flow rate, certificates of compliance for all covers used, flow rate for the covers installed in the 2x2 arrangement based on manufacturers specifications, sump depths, etc.). Anti-entrapment plan/devices must be compliance with the VGBA-2017.**OUTSTANDING (2025-07-16). The Anti-Entrapment Compliance Plan was reviewed, and discrepancies were noted. Specifically, the current sump dimensions were not in compliance with the manufacturer's requirements for the suction outlet cover. The operator was instructed to provide adequate documentation to prove that the current sump dimensions are allowed and acceptable for the main drain cover and is in compliance with the VGBA-2017 requirements.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- A discrepancy was observed between the chlorine reading on automated controller and manual testing. Manual test (FC): 3.55ppm Automated test: 2.33mg/LPlease ensure the automated controller is calibrated properly and consistent with manual testing.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pool volume was too low to allow the gutter system to be in operation. The pool must have adequate surface recirculation. Please increase the volume such that the gutter system can work properly.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Concerns over the anti-entrapment plan (needs updating to reflect the following: correct flow rate, certificates of compliance for all covers used, flow rate for the covers installed in the 2x2 arrangement based on manufacturers specifications, sump depths, etc.).Anti-entrapment plan/devices must be compliance with the VGBA-2017.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (25ES-183E00056) was rejected by the lab as the time of collection was not completed. Please submit a new water sample for the main pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
Nearby inspected facilities
- Eau Claire Athletic Club - Hot Tub
101 3 Street SW Calgary AB T2P 4G6
14 inspections
- Eau Claire Athletic Club - Pool Common Area
101 3 Street SW Calgary AB T2P 4G6
5 inspections
- Eau Claire Athletic Club - Cold Tub
101 3 Street SW Calgary AB T2P 4G6
17 inspections
- Eau Claire Athletic Club - Main Kitchen
101 3 Street SW Calgary AB T2P 4G6
2 inspections
- Eau Claire Athletic Club - Brooklynn's Cafe
101 3 Street SW Calgary AB T2P 4G6
1 inspection
- Eau Claire Athletic Club - Training Pool
101 3 Street SW Calgary AB T2P 4G6
15 inspections
- Aisthetikos Wellness & Advanced Medical Aesthetics
260 - 101 3 Street SW Calgary AB T2B 4G6
2 inspections
- Bread and Brew
201 - 440 2 Avenue SW Calgary AB T2P 5E9
1 inspection