Skip to content
Loading map…

Fairfield Inn & Suites by Marriott Airdrie - Whirlpool

911 Highland Park Cove NE Airdrie AB T4A 0R2 · Aquatic Facility

Inspection summary

Fairfield Inn & Suites by Marriott Airdrie - Whirlpool has been inspected 31 times by Alberta Health Services (Environmental Public Health) since February 8, 2024. The most recent inspection, on October 9, 2026, recorded 2 infractions.

6 of 31 inspections on record found no infractions at all. In the past 12 months there were 16 inspections with 16 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 26 times across 20 separate inspections, most recently on October 9, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times across 2 separate inspections, most recently on April 3, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 11 times across 11 separate inspections, most recently on April 3, 2025. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

31 inspections

  1. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on October 6, 2026, showed positive isolation of Pseudomonas aeruginosa. **Please treat pool water and resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The TURNOVER RATE for the hot tub was calculated to be 21.9mins**Adjust flow rate to ensure that the water in the hot tub completes a full turnover/recirculation within 20mins.
  2. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The TURNOVER RATE for the hot tub was calculated to be 21.9mins**Adjust flow rate to ensure that the water in the hot tub completes a full turnover/recirculation within 20mins.
  3. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample submitted on Aug 18th returned positive for total coliform. **Investigate concerns if any with pool and treatment system. Complete treatment of the pool and resubmit sample to the lab for testing.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The TURNOVER RATE for the hot tub was calculated to be 21.9mins**Adjust flow rate to ensure that the water in the hot tub completes a full turnover/recirculation within 20mins.
  4. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The TURNOVER RATE for the hot tub was calculated to be 21.9mins**Adjust flow rate to ensure that the water in the hot tub completes a full turnover/recirculation within 20mins.
  5. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on June 29, 2026, showed positive isolation of Pseudomonas aeruginosa. **Please treat pool water and resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The TURNOVER RATE for the hot tub was calculated to be 21.9mins**Adjust flow rate to ensure that the water in the hot tub completes a full turnover/recirculation within 20mins.
  6. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The TURNOVER RATE for the hot tub was calculated to be 21.9mins**Adjust flow rate to ensure that the water in the hot tub completes a full turnover/recirculation within 20mins.
  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on March 17, 2026, indicated presence of Pseudomonas aeruginosa.**Close hot tub**Complete thorough cleaning and treatment of pool and resubmit sample.
  9. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on March 12, 2026, indicated presence of Pseudomonas aeruginosa.**Treat pool and Resubmit sample.
  10. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on Jan 6, 2026, indicated presence of Total coliforms and Pseudomonas aeruginosa.**Treat pool and Resubmit sample.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The most recent bacteriological water sample indicated a presence of total coliform bacteria.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The most recent bacteriological water sample indicated a heterotropic plate count of 140 CFU/mL.
  13. Risk Management Inspection

    0 infractions

  14. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on November 4, 2025, showed positive isolation of Pseudomonas aeruginosa. **Please treat pool water and resample.
  15. Risk Management Inspection

    0 infractions

  16. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on October 21, 2025, showed positive isolation of Pseudomonas aeruginosa. **Please treat pool water and resample.
  17. Risk Management Inspection

    0 infractions

  18. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample collected on July 15, 2025 indicated presence of pseudomonas. **Please treat the pool and resample.
  19. Risk Management Inspection

    0 infractions

  20. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate exceeded max flow rate of 61GPM, flow meter was reading 70 GPM. Filtration rate was 14.3 GPM/sqft. Requirement:- Please adjust flow rate so it does not exceed the max flow rate for the filter.
  21. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on April 1, 2025, showed positive isolation of Pseudomonas aeruginosa. **Please treat pool water and resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on April 1, 2025, showed HPC count of 2800 CFU/ml. **Please treat pool water and resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combine chlorine (CC) value of the pool water was measured at 2.74ppm.**It is recommended to maintain CC value below 1.0ppm
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. There was no pool safety plan available for the pool.**Develop a pool safety plan.
  22. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combine chlorine (CC) value of the pool water was measured at 2.74ppm.**It is recommended to maintain CC value below 1.0ppm
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. There was no pool safety plan available for the pool.**Develop a pool safety plan.
  23. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on December 31, 2024, showed positive isolation of Pseudomonas aeruginosa. **Please treat pool water and resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on December 31, 2024, showed HPC count of 9160 CFU/ml. **Please treat pool water and resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. **Please ensure plan is updated with maximum flow rate.2. The incident response plan available on site for water contamination incident was incomplete.**Modify current plan in place to show actions to be taken in the event of solid/diarrheal fecal, vomit or blood contamination.3. The sanitation plan available on site was incomplete. **Please modify plan to show frequency of cleaning, chemicals used and person responsible. Include a sanitation log that is completed to indicate cleaning is done.4. There was no pool safety plan available for the pool.**Develop a pool safety plan.
  24. Demand Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. **Please ensure plan is updated with maximum flow rate.2. The incident response plan available on site for water contamination incident was incomplete.**Modify current plan in place to show actions to be taken in the event of solid/diarrheal fecal, vomit or blood contamination.3. The sanitation plan available on site was incomplete. **Please modify plan to show frequency of cleaning, chemicals used and person responsible. Include a sanitation log that is completed to indicate cleaning is done.4. There was no pool safety plan available for the pool.**Develop a pool safety plan.
  25. Monitoring Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. **Please ensure plan is updated with maximum flow rate.2. The incident response plan available on site for water contamination incident was incomplete.**Modify current plan in place to show actions to be taken in the event of solid/diarrheal fecal, vomit or blood contamination.3. The sanitation plan available on site was incomplete. **Please modify plan to show frequency of cleaning, chemicals used and person responsible. Include a sanitation log that is completed to indicate cleaning is done.4. There was no pool safety plan available for the pool.**Develop a pool safety plan.
  26. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on August 20, 2024, showed HPC count of 110 CFU/ml.**Please treat pool water and resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. Please ensure plan is updated with maximum flow rate.2. No incident response plan was on-site for water contamination incidents. Please ensure there is a written policy for actions to take after contamination. 3. No sanitation plan was available for the pool.**Ensure sanitation plan is developed to indicate chemicals used for cleaning the pool and cleaning schedule
  27. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample collected on July 09, 2024 indicated presence of pseudomonas. **Please treat the pool and resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. Please ensure plan is updated with maximum flow rate.2. No incident response plan was on-site for water contamination incidents. Please ensure there is a written policy for actions to take after contamination. 3. No sanitation plan was available for the pool.**Ensure sanitation plan is developed to indicate chemicals used for cleaning the pool and cleaning schedule
  28. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on May 07, 2024 indicate high levels of HPC - 240 CFU/ml. **Please treat pool water and resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. Please ensure plan is updated with maximum flow rate.2. No incident response plan was on-site for water contamination incidents. Please ensure there is a written policy for actions to take after contamination. 3. No sanitation plan was available for the pool.**Ensure sanitation plan is developed to indicate chemicals used for cleaning the pool and cleaning schedule
  29. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total coliform was present in the pool sample submitted on March 05, 2024.**Please treat pool water and resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. Please ensure plan is updated with maximum flow rate.2. No incident response plan was on-site for water contamination incidents. Please ensure there is a written policy for actions to take after contamination. 3. No sanitation plan was available for the pool.**Ensure sanitation plan is developed to indicate chemicals used for cleaning the pool and cleaning schedule
  30. Monitoring Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. Please ensure plan is updated with maximum flow rate.2. No incident response plan was on-site for water contamination incidents. Please ensure there is a written policy for actions to take after contamination. 3. No sanitation plan was available for the pool.**Ensure sanitation plan is developed to indicate chemicals used for cleaning the pool and cleaning schedule
  31. Demand Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. Flow rate on anti-entrapment plan was not properly calculated. Please ensure plan is updated with maximum flow rate.2. No incident response plan was on-site for water contamination incidents. Please ensure there is a written policy for actions to take after contamination.

Nearby inspected facilities

Own this business? Add a badge to your website