  1. Risk Management Inspection

    6 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for skin cleansing prior to services, antiseptic use, and accidental cuts were available.
    • 11. Is post-service care provided by personal service workers following any personal service or accident where a client's skin or mucous membrane is cut or punctured during a personal service, or when energy-emitting equipment is used?
      • No after-treatment care instructions were available for laser and microblading services.
    • 20. Is reusable equipment disinfected properly?
      • No high-level disinfectant was available for disinfection of tools. Obtain a proper high-level disinfectant.
    • 20. Is reusable equipment disinfected properly?
      • No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
    • 20. Is reusable equipment disinfected properly?
      • No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
    • 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
      • No paper towel dispenser was available in the washroom. Please provide a proper paper towels dispenser.
  2. Initial Inspection

    14 infractions

    • 02. Has the operator notified the RHA of the existence of a personal service business, including contact and location information, as well as all personal services currently offered or new personal services that will be offered for facilities and/or special events?
      • The owner of the personal service business did not submit a notification about the business to the Alberta Health Services. Submit the notification to AHS.
    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for skin cleansing prior to services, antiseptic use, and accidental cuts were available.
    • 11. Is post-service care provided by personal service workers following any personal service or accident where a client's skin or mucous membrane is cut or punctured during a personal service, or when energy-emitting equipment is used?
      • No after-treatment care instructions were available for laser, microblading and microneedling services.
    • 20. Is reusable equipment disinfected properly?
      • No high-level disinfectant was available for disinfection of tools. Obtain a proper high-level disinfectant.
    • 20. Is reusable equipment disinfected properly?
      • No soaking tray was available for disinfection of the tools. The semi-critical tools must be disinfected by soaking in a high-level disinfectant.
    • 20. Is reusable equipment disinfected properly?
      • No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
    • 20. Is reusable equipment disinfected properly?
      • No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
    • 20. Is reusable equipment disinfected properly?
      • Unapproved disinfectant (alcohol, no DIN available) was reported to be used for machines disinfection. Ensure that an approved disinfectant is used for machines disinfection.
    • 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
      • Some needles and microblading pens did not have a proper sterility assurance documentation. Please discontinue.
    • 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
      • The Inmode laser and Light Therapy machines did not have manufacturer's instructions. Ensure that the manufacturer's instructions are available or discontinue use of the equipment.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Some cosmetic products were used against manufacturer's instructions: some products were expired. Please discontinue use.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Some cosmetic products did not have proper labels: some products were unlabelled and some were missing ingredients. Ensure that all cosmetic products have appropriate labels.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Wax rollers were available but not used. Discussed: wax rollers cannot be used due to wax contamination during services.
    • 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
      • No paper towel dispenser was available in the washroom. Please provide a proper paper towels dispenser.