Freedom Beauty & Wellness

14920 45 Avenue NW Edmonton AB T6H 5T5 · Personal Services

3 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
      • No paper towels dispenser/paper towel holder was available for paper towels at the hand sink.
  3. Monitoring Inspection

    11 infractions

    • 02. Has the operator notified the RHA of the existence of a personal service business, including contact and location information, as well as all personal services currently offered or new personal services that will be offered for facilities and/or special events?
      • The owner of the personal service business did not submit a notification about the business to the Alberta Health Services. Submitted during the inspection.
    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for skin cleansing prior to services, antiseptic use, and reprocessing sink decontamination were available.
    • 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
      • No paper towels dispenser/paper towel holder was available for paper towels at the hand sink.
    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Sterility assurance documentation for sterile equipment was not retained with the clients' records. Ensure that sterility assurance documentation for all critical equipment used during services is retained with clients' forms.
    • 13. Is single-use or uncleanable equipment being used as intended (Critical)?
      • A sharp re-usable used for extractions during facials was observed. Ensure that all sharp tools used for extractions are discarded after one use.
    • 20. Is reusable equipment disinfected properly?
      • The concentration of the high-level disinfectant (Preempt CS20) was inadequate - tested using the PHI's test strip. Ensure that the concentration is sufficient prior to disinfection.
    • 20. Is reusable equipment disinfected properly?
      • No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
    • 20. Is reusable equipment disinfected properly?
      • No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
    • 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
      • The machines Dermalase (IPL), Dermastamp (microneedling) and Pologen Expert More did not have manufacturer's instructions. Ensure that the manufacturer's instructions are available or discontinue use of the equipment.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Some cosmetic products did not have appropriate labels (no ingredients or no labels). Ensure that all cosmetic products have appropriate labels.
    • 33. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Non-Critical)?
      • Preempt RTU used for disinfection of equipment/surfaces had unreadable expiry date. Please obtain an appropriate disinfectant.