Genesis Place - Whirlpool

800 East Lake Boulevard NE Airdrie AB T4A 2K9 · Aquatic Facility

Inspection summary

Genesis Place - Whirlpool has been inspected 16 times by Alberta Health Services (Environmental Public Health) since November 23, 2023. The most recent inspection, on September 1, 2026, recorded 1 infraction.

4 of 16 inspections on record found no infractions at all. In the past 12 months there were 8 inspections with 16 infractions recorded. The higher-risk findings here relate to: Chemicals and toxic substances and Pool and spa water quality.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 13 times across 11 separate inspections, most recently on September 1, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 7 times across 6 separate inspections, most recently on August 21, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

16 inspections

  1. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample submitted on Aug 18th returned with an elevated HPC value of 210CFU/ml.**Resubmit sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
  3. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
  4. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on June 16th was not processed due to incorrect date**Resubmit sample to the lab.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
  5. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
  6. Risk Management Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on Feb 10, 2026 was not processed because the time of collection was not indicated.**Resubmit sample
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
  7. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on Feb 3, 2026 was not processed because the bottle was missing the ID number.**Resubmit sample
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH level was measured at 6.58**Maintain pH level between 6.8 and 7.6.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The values of the pH and Free chlorine obtained from automated controller is not consistent with the values obtained from manual testing.**Investigate and repair automated system.**Clean/service probes to ensure the automated system is completing accurate readings of the pool's water chemistry
  8. Monitoring Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH level was measured at 6.58**Maintain pH level between 6.8 and 7.6.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 49 ppm. - Maintain Alkalinity between 60 - 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The values of the pH and Free chlorine obtained from automated controller is not consistent with the values obtained from manual testing.**Investigate and repair automated system.**Clean/service probes to ensure the automated system is completing accurate readings of the pool's water chemistry
  9. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity was measured at 53 ppm. - Maintain Alkalinity between 60 - 180 ppm.
  10. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine level was measured at 1.56ppm**It is recommended to maintain the combined chlorine level below 1.0ppm at all times.
  11. Monitoring Inspection

    0 infractions

  12. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was recorded at 3.68 ppm.- Combined chlorine should be maintained at the lowest level possible.-It is recommended to keep combined chlorine value below 1.0ppm
  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on April 30th, 2024 indicate high levels of HPC - 260 CFU/ml. **Please treat pool water and resample.
  14. Monitoring Inspection

    0 infractions

  15. Demand Inspection

    0 infractions

  16. Monitoring Inspection

    0 infractions