Skip to content
Loading map…

Hampton Inn & Suites by Hilton St. Albert - Swimming Pool

585 Mistatim Way NW Edmonton AB T6V 0M8 · Aquatic Facility

Inspection summary

Hampton Inn & Suites by Hilton St. Albert - Swimming Pool has been inspected 14 times by Alberta Health Services (Environmental Public Health) since December 4, 2023. The most recent inspection, on September 22, 2026, found no infractions.

7 of 14 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 8 times across 7 separate inspections, most recently on September 22, 2026. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on July 8, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded once on July 8, 2025. For example: Are proper testing, monitoring, and other records being properly maintained?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded once on February 25, 2025. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

14 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The filtration rate was 16.5 GPM/sq.ft. which is too fast. Ensure flow rate is maintained between 57 GPM & 72 GPM.
  3. Risk Management Inspection

    0 infractions

  4. Risk Management Inspection

    0 infractions

  5. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity of the swimming pool was tested to be at 22ppm during the time of inspection.Please ensure that the total alkalinity is maintained between 60-180ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated controller readings are inconsistent with manual testing, the automated reading for pH were 7.22 and the manual testing for pH was 6.96. Please ensure that the automated reading for the controller is more consistent with manual testing. Consider recalibration or cleaning the sensors.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Inconsistencies in daily record keeping observed during the inspection, some chemical water parameters were not consistently being tested every day.Please ensure that the daily testing log sheet is filled out in its entirety every day of operation.
  6. Risk Management Inspection

    0 infractions

  7. Risk Management Inspection

    2 infractions

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main drain covers have expired.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment plan is required to be provided to this office.
  8. Risk Management Inspection

    0 infractions

  9. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • One of the two lectranator's were in disrepair. Parts are on order. Please provide this office with further details as to repairs required and proposed timeframe for completion of repairs.
  10. Risk Management Inspection

    0 infractions

  11. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter was not operational. Repair/replace.
  12. Risk Management Inspection

    0 infractions

  13. Risk Management Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on 2023-11-29 [Accession: WE-23-0128285] was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample collected on 2023-12-06 [Accession #: WE-23-0131011] was unsatisfactory: HPC: 130 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  14. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on 2023-11-29 [Accession: WE-23-0128285] was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.