Hampton Inn & Suites - Hot Tub
128 Leva Avenue Red Deer County AB T4E 1B9 · Aquatic Facility
Inspection summary
Hampton Inn & Suites - Hot Tub has been inspected 15 times by Alberta Health Services (Environmental Public Health) since December 5, 2023. The most recent inspection, on April 28, 2026, found no infractions.
4 of 15 inspections on record found no infractions at all. In the past 12 months there were 6 inspections with 5 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Food temperature control.
The last 2 inspections in a row found no infractions. The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 11 times across 8 separate inspections, most recently on January 2, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Critical)?
Food temperature controlHigher risk
Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.
Recorded 4 times across 4 separate inspections, most recently on March 24, 2026. For example:
Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
Permits, records and postingLower risk
Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.
Recorded once on August 27, 2024. For example:
Are proper testing, monitoring, and other records being properly maintained?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
15 inspections
- Monitoring Inspection
0 infractions
- Demand Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There are cracks in the basin surrounding the east drain cover in the whirlpool. These cracks raise concerns about potentially compromising the structural integrity and effectiveness of both the drain cover and the pool basin. Please have this assessed by a qualified pool technician and submit a written report to our office verifying whether the area is in acceptable working condition.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The bacteriological water sample collected on December 30, 2025, was present for Pseudomonas aeruginosa. The inspector contacted the general manager, Michael, and informed him of the water sample results. Michael stated that the whirlpool is planned to be closed and drained for maintenance. The facility anticipates reopening and resampling the water during the week of January 12, 2026.Please ensure that the pool water is treated and a resample is submitted.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There are cracks in the basin surrounding the east drain cover in the whirlpool. These cracks raise concerns about potentially compromising the structural integrity and effectiveness of both the drain cover and the pool basin. Please have this assessed by a qualified pool technician and submit a written report to our office verifying whether the area is in acceptable working condition.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There are cracks in the basin surrounding the east drain cover in the whirlpool. These cracks raise concerns about potentially compromising the structural integrity and effectiveness of both the drain cover and the pool basin. Please have this assessed by a qualified pool technician and submit a written report to our office verifying whether the area is in acceptable working condition.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There are cracks in the basin surrounding the east drain cover in the whirlpool. These cracks raise concerns about potentially compromising the structural integrity and effectiveness of both the drain cover and the pool basin. Please have this assessed by a qualified pool technician and submit a written report to our office verifying whether the area is in acceptable working condition.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Monitoring Inspection
0 infractions
- Demand Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- December 10, 2024-The whirlpool was shut down due to a leak in the pipe. The facility was in the process of repairing the pipe, and the health inspector could not verify if the outstanding violations were resolved. October 21, 2024- The flow meter is operational and in good repair. - The directional jets are not operational due to the whirlpool's pump according to the operator. The facility has ordered a new pump, and it is planned to be installed this week. August 28, 2024- The flow rate could not be determined because the flow meter was not functional. Ensure that the flow meter is in good repair. - The directional jets are not functional. Ensure that the directional jets are in good repair. - The general manager stated that a pool technician will be coming by next week to assess and repair the whirlpool. December 5, 2023- The flow rate of the whirlpool is 225 LPM (approx. 59.4 GPM). - The directional jets are planned to be repaired or replaced. August 28, 2023Whirlpool volume: 750 gallons (2.839 m^3)Flow rate: 45 GPMRecirculation rate: 16.67 mins1) The recirculation rate for the whirlpool is 16.67 mins. Past written records indicate the flow rate to be between 50 to 60 GPM. For a whirlpool with a volume of less than four cubic metres, the recirculation rate must be 15 mins or less. Ensure that the recirculation rate is 15 mins or less. 2) Most of the directional jets in the whirlpool are not functional; only two jets are operational. The operator stated that the directional jets will be repaired/replaced within ten days. Ensure that directional jets are in good repair and operational.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- October 21, 2024- The flow meter is operational and in good repair. - The directional jets are not operational due to the whirlpool's pump according to the operator. The facility has ordered a new pump, and it is planned to be installed this week. August 28, 2024- The flow rate could not be determined because the flow meter was not functional. Ensure that the flow meter is in good repair. - The directional jets are not functional. Ensure that the directional jets are in good repair. - The general manager stated that a pool technician will be coming by next week to assess and repair the whirlpool. December 5, 2023- The flow rate of the whirlpool is 225 LPM (approx. 59.4 GPM). - The directional jets are planned to be repaired or replaced. August 28, 2023Whirlpool volume: 750 gallons (2.839 m^3)Flow rate: 45 GPMRecirculation rate: 16.67 mins1) The recirculation rate for the whirlpool is 16.67 mins. Past written records indicate the flow rate to be between 50 to 60 GPM. For a whirlpool with a volume of less than four cubic metres, the recirculation rate must be 15 mins or less. Ensure that the recirculation rate is 15 mins or less. 2) Most of the directional jets in the whirlpool are not functional; only two jets are operational. The operator stated that the directional jets will be repaired/replaced within ten days. Ensure that directional jets are in good repair and operational.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- October 21, 2024The whirlpool was not operational during the inspection and the pool water was drained. The facility plans to refill the pool later in the day. August 27, 2024The one of the skimmer baskets for the whirlpool is floating in the water and not operating correctly. Please ensure that all the skimmer baskets are in good repair and functional.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- October 21, 2024- The flow meter is operational and in good repair. - The directional jets are not operational due to the whirlpool's pump according to the operator. The facility has ordered a new pump, and it is planned to be installed this week. August 28, 2024- The flow rate could not be determined because the flow meter was not functional. Ensure that the flow meter is in good repair. - The directional jets are not functional. Ensure that the directional jets are in good repair. - The general manager stated that a pool technician will be coming by next week to assess and repair the whirlpool. December 5, 2023- The flow rate of the whirlpool is 225 LPM (approx. 59.4 GPM). - The directional jets are planned to be repaired or replaced. August 28, 2023Whirlpool volume: 750 gallons (2.839 m^3)Flow rate: 45 GPMRecirculation rate: 16.67 mins1) The recirculation rate for the whirlpool is 16.67 mins. Past written records indicate the flow rate to be between 50 to 60 GPM. For a whirlpool with a volume of less than four cubic metres, the recirculation rate must be 15 mins or less. Ensure that the recirculation rate is 15 mins or less. 2) Most of the directional jets in the whirlpool are not functional; only two jets are operational. The operator stated that the directional jets will be repaired/replaced within ten days. Ensure that directional jets are in good repair and operational.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The one of the skimmer baskets for the whirlpool is floating in the water and not operating correctly. Please ensure that all the skimmer baskets are in good repair and functional.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- August 28, 2024- The flow rate could not be determined because the flow meter was not functional. Ensure that the flow meter is in good repair. - The directional jets are not functional. Ensure that the directional jets are in good repair. - The general manager stated that a pool technician will be coming by next week to assess and repair the whirlpool. December 5, 2023- The flow rate of the whirlpool is 225 LPM (approx. 59.4 GPM). - The directional jets are planned to be repaired or replaced. August 28, 2023Whirlpool volume: 750 gallons (2.839 m^3)Flow rate: 45 GPMRecirculation rate: 16.67 mins1) The recirculation rate for the whirlpool is 16.67 mins. Past written records indicate the flow rate to be between 50 to 60 GPM. For a whirlpool with a volume of less than four cubic metres, the recirculation rate must be 15 mins or less. Ensure that the recirculation rate is 15 mins or less. 2) Most of the directional jets in the whirlpool are not functional; only two jets are operational. The operator stated that the directional jets will be repaired/replaced within ten days. Ensure that directional jets are in good repair and operational.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Some of the pool water testing reagents were expired in 2023 or in July 2024. Please ensure that the reagents are not expired.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- December 5, 2023- The flow rate of the whirlpool is 225 LPM (approx. 59.4 GPM). - The directional jets are planned to be repaired or replaced. August 28, 2023Whirlpool volume: 750 gallons (2.839 m^3)Flow rate: 45 GPMRecirculation rate: 16.67 mins1) The recirculation rate for the whirlpool is 16.67 mins. Past written records indicate the flow rate to be between 50 to 60 GPM. For a whirlpool with a volume of less than four cubic metres, the recirculation rate must be 15 mins or less. Ensure that the recirculation rate is 15 mins or less. 2) Most of the directional jets in the whirlpool are not functional; only two jets are operational. The operator stated that the directional jets will be repaired/replaced within ten days. Ensure that directional jets are in good repair and operational.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The bacteriological water sample collected on July 10, 2024, has a heterotrophic plate count of 390 CFU/mL. Please ensure that the pool water is resampled.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- December 5, 2023- The flow rate of the whirlpool is 225 LPM (approx. 59.4 GPM). - The directional jets are planned to be repaired or replaced. August 28, 2023Whirlpool volume: 750 gallons (2.839 m^3)Flow rate: 45 GPMRecirculation rate: 16.67 mins1) The recirculation rate for the whirlpool is 16.67 mins. Past written records indicate the flow rate to be between 50 to 60 GPM. For a whirlpool with a volume of less than four cubic metres, the recirculation rate must be 15 mins or less. Ensure that the recirculation rate is 15 mins or less. 2) Most of the directional jets in the whirlpool are not functional; only two jets are operational. The operator stated that the directional jets will be repaired/replaced within ten days. Ensure that directional jets are in good repair and operational.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- December 5, 2023- The flow rate of the whirlpool is 225 LPM (approx. 59.4 GPM). - The directional jets are planned to be repaired or replaced. August 28, 2023Whirlpool volume: 750 gallons (2.839 m^3)Flow rate: 45 GPMRecirculation rate: 16.67 mins1) The recirculation rate for the whirlpool is 16.67 mins. Past written records indicate the flow rate to be between 50 to 60 GPM. For a whirlpool with a volume of less than four cubic metres, the recirculation rate must be 15 mins or less. Ensure that the recirculation rate is 15 mins or less. 2) Most of the directional jets in the whirlpool are not functional; only two jets are operational. The operator stated that the directional jets will be repaired/replaced within ten days. Ensure that directional jets are in good repair and operational.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Nearby inspected facilities
- Hampton Inn & Suites - Pool Common Area
128 Leva Avenue Red Deer County AB T4E 1B9
10 inspections
- Hampton Inn & Suites - Food
128 Leva Avenue Red Deer County AB T4E 1B9
3 inspections
- Hampton Inn & Suites - Swimming Pool
128 Leva Avenue Red Deer County AB T4E 1B9
23 inspections
- Microtel Inn & Suites Red Deer - Swimming Pool
126 Leva Avenue Red Deer County AB T4E 1B9
4 inspections
- Microtel Inn & Suites Red Deer - Food
126 Leva Avenue Red Deer County AB T4E 1B9
1 inspection
- Microtel Inn & Suites Red Deer - Common Area
126 Leva Avenue Red Deer County AB T4E 1B9
2 inspections
- Microtel Inn & Suites Red Deer - Whirlpool
126 Leva Avenue Red Deer County AB T4E 1B9
3 inspections
- Boston Pizza 269
122 Leva Avenue Red Deer County AB T4E 1B2
8 inspections