Skip to content
Loading map…

Hampton Inn & Suites - Swimming Pool

128 Leva Avenue Red Deer County AB T4E 1B9 · Aquatic Facility

Inspection summary

Hampton Inn & Suites - Swimming Pool has been inspected 23 times by Alberta Health Services (Environmental Public Health) since December 5, 2023. The most recent inspection, on April 28, 2026, found no infractions.

13 of 23 inspections on record found no infractions at all. In the past 12 months there were 8 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The last 4 inspections in a row found no infractions. The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 11 times across 10 separate inspections, most recently on February 13, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

23 inspections

  1. Monitoring Inspection

    0 infractions

  2. Demand Inspection

    0 infractions

  3. Demand Inspection

    0 infractions

  4. Risk Management Inspection

    0 infractions

  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacteriological water sample collected on February 10, 2026, has a heterotrophic plate count of 180 CFU/mL. Please ensure that the pool water is resampled.
  6. Risk Management Inspection

    0 infractions

  7. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate: 90 GPM Pentair Triton II TR-100- Filtration area: 4.91 sq. ft. - Max filtration: 15 GPM/sq. ft.Based on the operational flow rate of 90 GPM, this exceeds the filter's max filtration and is in contravention to Section 3.3.1 of the Alberta Health Pool Standards, July 2014 (amended January 2018). Please ensure that the max filtration does not exceed 15 GPM/sq. ft.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The suction outlet cover for the east main drain is damaged with a broken corner. The facility must: a) Replace the east main drain suction outlet cover and ensure it complies with all applicable legislation and standards. It must be installed according to the manufacturer’s instructions.b) Review the anti-entrapment plan and submit an updated anti-entrapment compliance plan to this office.
  8. Demand Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The suction outlet cover for the east main drain is damaged with a broken corner. The facility must: a) Replace the east main drain suction outlet cover and ensure it complies with all applicable legislation and standards. It must be installed according to the manufacturer’s instructions.b) Review the anti-entrapment plan and submit an updated anti-entrapment compliance plan to this office.
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacteriological water sample collected on July 2, 2025, has a heterotrophic plate count of 110 CFU/mL. Please ensure that the pool water is resampled.
  11. Monitoring Inspection

    0 infractions

  12. Demand Inspection

    0 infractions

  13. Monitoring Inspection

    0 infractions

  14. Risk Management Inspection

    0 infractions

  15. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • May 17, 2024The operator stated that a water sample for the swimming pool was submitted on May 13, 2024. The results of the water sample have not been received by the operator or Environmental Public Health. May 10 2024The bacteriological water sample collected on May 8, 2024, had T C (Total Coliform) Present. Please super-chlorinate the pool and keep the pool CLOSED pending a satisfactory sample result. Please submit a sample on Monday May 13. May 6, 2024The bacteriological water sample collected on May 1, 2024, had a heterotrophic plate count of >57000 CFU/mL. Please super-chlorinate the pool and ensure that the pool water is resampled. April 29, 2024The bacteriological water sample collected on April 24, 2024, had a heterotrophic plate count of 2490 CFU/mL. Please ensure that the pool water is resampled.
  16. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • May 10 2024The bacteriological water sample collected on May 8, 2024, had T C (Total Coliform) Present. Please super-chlorinate the pool and keep the pool CLOSED pending a satisfactory sample result. Please submit a sample on Monday May 13. May 6, 2024The bacteriological water sample collected on May 1, 2024, had a heterotrophic plate count of >57000 CFU/mL. Please super-chlorinate the pool and ensure that the pool water is resampled. April 29, 2024The bacteriological water sample collected on April 24, 2024, had a heterotrophic plate count of 2490 CFU/mL. Please ensure that the pool water is resampled.
  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • May 6, 2024The bacteriological water sample collected on May 1, 2024, had a heterotrophic plate count of >57000 CFU/mL. Please super-chlorinate the pool and ensure that the pool water is resampled. April 29, 2024The bacteriological water sample collected on April 24, 2024, had a heterotrophic plate count of 2490 CFU/mL. Please ensure that the pool water is resampled.
  18. Risk Management Inspection

    0 infractions

  19. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacteriological water sample collected on April 24, 2024, had a heterotrophic plate count of 2490 CFU/mL. Please ensure that the pool water is resampled.
  20. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacteriological water sample collected on April 10, 2024, had a heterotrophic plate count of 3080 CFU/mL. Please ensure that the pool water is resampled.
  21. Risk Management Inspection

    0 infractions

  22. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacteriological water sample collected on March 26, 2024, had a heterotrophic plate count of 1130 CFU/mL. Please ensure that the pool water is resampled.
  23. Demand Inspection

    0 infractions

Nearby inspected facilities