Holiday Inn Airport - Swimming Pool
1250 Mckinnon Drive NE Calgary AB T2E 7T7 · Aquatic Facility
8 inspections
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. The last bacteriological water sample on file was submitted June 11, 2024. During the inspection the Operator stated they drop off weekly samples every Tuesday.**November 18, 2025: Spoke with the General Manager to inform them of sampling history and was informed weekly samples are dropped off, but was not sure what information was being provided on the requisition form.**November 24, 2025: bacteriological water sample collected for both basins during the inspection. Samples were going to be dropped off by the Operator at the Provincial Lab later after the inspection. COMPLETE THE FOLLOWING:1. Ensure the requisition forms are completed properly and include the access number to ensure the sample is linked to the facility's file.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. The last bacteriological water sample on file was submitted June 11, 2024. During the inspection the Operator stated they drop off weekly samples every Tuesday.**November 18, 2025: Spoke with the General Manager to inform them of sampling history and was informed weekly samples are dropped off, but was not sure what information was being provided on the requisition form.COMPLETE THE FOLLOWING:1. Ensure the requisition forms are completed properly and include the access number to ensure the sample is linked to the facility's file.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- 1. The alkalinity measured greater than 200ppm. The Operator adjusted the alkalinity, and time was given to allow for the water chemistry to adjust. The alkalinity was re-tested and measured 200ppm.**November 20, 2025: alkalinity measured greater than 180ppm. Several tests were taken during the inspection.COMPLETE THE FOLLOWING:1. Ensure the alkalinity is maintained between 60ppm - 180ppm at all times.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
6 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. The last bacteriological water sample on file was submitted June 11, 2024. During the inspection the Operator stated they drop off weekly samples every Tuesday.**November 18, 2025: Spoke with the General Manager to inform them of sampling history and was informed weekly samples are dropped off, but was not sure what information was being provided on the requisition form.COMPLETE THE FOLLOWING:1. Ensure the requisition forms are completed properly and include the access number to ensure the sample is linked to the facility's file.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- 1. The pH measured 8.09. pH was adjusted at the automated controller and time was given to allow chemistry to adjust. pH was re-tested afterwards and measured 7.87. COMPLETE THE FOLLOWING:1. Ensure the pH is maintained between 6.8 - 7.6 at all times.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- 1. The alkalinity measured greater than 200ppm. The Operator adjusted the alkalinity, and time was given to allow for the water chemistry to adjust. The alkalinity was re-tested and measured 200ppm.COMPLETE THE FOLLOWING:1. Ensure the alkalinity is maintained between 60ppm - 180ppm at all times.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- **CORRECTED**1. Hair and debris noted in the North East and South skimmer baskets. Debris removed during the inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. There was some chemical buildup noted on the automated controller probes. Manual tests measured pH 8.09 and 7.87, and the automated reading was 7.1 during the inspection.COMPLETE THE FOLLOWING:1. Please have the automated controllers serviced and re-calibrated to ensure they are operating correctly and getting accurate readings.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. The log for the swimming pool that was hung on the wall was dated September 8 to 14, 2025. There were no other more recent logs to demonstrate that water chemistry is checked daily. The Operator stated they had not checked the water chemistry for the day.COMPLETE THE FOLLOWING:1. Ensure records are completed daily and are accurate.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine was measured at 1.96 milligrams per litre during the inspection.-Please reduce and maintain the pool combined chlorine as low as possible to ensure bathers' comfort.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The filtration rate for the swimming pool was too fast, calculated at 16.1 GPM per square foot.-Please the filtration rate to comply with the Swimming Pool Standards.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Swimming pool water sample collected on 2023-11-14 showed HPC was enumerated at 240 CFU/mL.-Please treat the swimming pool in accordance with AHS unsatisfactory water sample.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Pool water chemical parameters not daily documented.-Please daily record water chemical parameters to ensure proper daily monitoring.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Pool water chemical parameters not daily documented.-Please daily record water chemical parameters to ensure proper daily monitoring.
- 16. Are proper testing, monitoring, and other records being properly maintained?