Maria_Brow_Lash.Art
645 - 11025 26 Avenue NW Edmonton AB T6J 5V3 · Personal Services
3 inspections
- Risk Management Inspection
0 infractions
- Risk Management Inspection
3 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- No written procedures for skin cleansing prior to services and antiseptic use were available.
- 20. Is reusable equipment disinfected properly?
- No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
- 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
- The reprocessing area was located in the bathroom. Bathroom sink was used for tools washing. Provide a designated reprocessing sink, which is not located in the bathroom.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- Initial Inspection
8 infractions
- 02. Has the operator notified the RHA of the existence of a personal service business, including contact and location information, as well as all personal services currently offered or new personal services that will be offered for facilities and/or special events?
- The owner of the personal service business did not submit a notification about the business to the Alberta Health Services. Submitted.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- No written procedures for skin cleansing prior to services and antiseptic use were available.
- 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
- Unacceptable antiseptic product was used for skin preparation: no DIN or NPN was available.
- 20. Is reusable equipment disinfected properly?
- Intermediate-level disinfectant (Preempt RTU) has been used for semi-critical tools disinfection. Approved high-level disinfectant is required.
- 20. Is reusable equipment disinfected properly?
- No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
- 20. Is reusable equipment disinfected properly?
- No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
- 26. Are cosmetic products appropriate for their intended use and being handled properly?
- Some cosmetic products did not have appropriate labels (labels missing or no ingredients listed). Ensure that all cosmetic products have appropriate labels.
- 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
- The reprocessing area was located in the bathroom. Bathroom sink was used for tools washing. Provide a designated reprocessing sink, which is not located in the bathroom.
- 02. Has the operator notified the RHA of the existence of a personal service business, including contact and location information, as well as all personal services currently offered or new personal services that will be offered for facilities and/or special events?