Meadow Spa - Hot Tub
345 Banff Avenue Banff AB T1L 1H8 · Aquatic Facility
7 inspections
- Demand Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was low; 49 ppm- Raise the alkalinity so it is within the 60-180 ppm range.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Monday May 4th, 2026, had Total Coliforms present. - Operators were informed to treat and re-sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was low; 49 ppm- Raise the alkalinity so it is within the 60-180 ppm range.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Monday May 4th, 2026, had Pseudomonas isolated. - Operators were informed to treat and re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Monday May 4th, 2026, had Total Coliforms present. - Operators were informed to treat and re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Monday May 4th, 2026, had an HPC of 57,000 CFU/ml. - Operators were informed to treat and re-sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was low; 49 ppm- Raise the alkalinity so it is within the 60-180 ppm range.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was low; 49 ppm- Raise the alkalinity so it is within the 60-180 ppm range.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Monday July 14th, 2025, was not processed. Wrong date on the form. - Operators were informed to submit a re-sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was low; 34 ppm- Raise the alkalinity so it is within the 60-180 ppm range.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow meter on the circulation system is maxed out, unable to get accurate reading for the flow of the circulation system. - Replace the flow meter with one with a larger range to determine accurate flow for the system.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was low; 34 ppm- Raise the alkalinity so it is within the 60-180 ppm range.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow meter on the circulation system is maxed out, unable to get accurate reading for the flow of the circulation system. - Replace the flow meter with one with a larger range to determine accurate flow for the system.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1) There was a crack in the plaster of the basin. - Repair the basin.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?