Movati Athletic - Women's Whirlpool

17020 Hiller Road SW Edmonton AB T6W 4H3 · Aquatic Facility

8 inspections

  1. Monitoring Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Skimmers require cleaning.
  3. Monitoring Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Skimmers require cleaning.
  4. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 13.74 gpm/sq ft based on a filtration area of 7.06 sq ft (with flow rate 97 gpm), which exceeds the maximum allowed rate of filtration 12.5 gpm/sq ft. Note: the flow rate cannot exceed 88 gpm for proper rate of filtration (and should not be below 60 gpm).
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Skimmers require cleaning.
  5. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 24EN-282E00762 submitted on October 8, 2024, was unsatisfactory: HPC 370.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 13.74 gpm/sq ft based on a filtration area of 7.06 sq ft (with flow rate 97 gpm), which exceeds the maximum allowed rate of filtration 12.5 gpm/sq ft. Note: the flow rate cannot exceed 88 gpm for proper rate of filtration (and should not be below 60 gpm).
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Skimmers require cleaning.
  6. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 13.74 gpm/sq ft based on a filtration area of 7.06 sq ft (with flow rate 97 gpm), which exceeds the maximum allowed rate of filtration 12.5 gpm/sq ft. Note: the flow rate cannot exceed 88 gpm for proper rate of filtration (and should not be below 60 gpm).
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Skimmers require cleaning.
  7. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample WE-24-0014506 submitted on February 13, 2024, was unsatisfactory: HPC 230.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 13.74 gpm/sq ft based on a filtration area of 7.06 sq ft (with flow rate 97 gpm), which exceeds the maximum allowed rate of filtration 12.5 gpm/sq ft. Note: the flow rate cannot exceed 88 gpm for proper rate of filtration (and should not be below 60 gpm).
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Skimmers require cleaning.
  8. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 13.74 gpm/sq ft based on a filtration area of 7.06 sq ft (with flow rate 97 gpm), which exceeds the maximum allowed rate of filtration 12.5 gpm/sq ft. Note: the flow rate cannot exceed 88 gpm for proper rate of filtration (and should not be below 60 gpm).
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Skimmers require cleaning.