Sierras Of Tuscany - Whirlpool

223 Tuscany Springs Boulevard NW Calgary AB T3L 2M2 · Aquatic Facility

Inspection summary

Sierras Of Tuscany - Whirlpool has been inspected 6 times by Alberta Health Services (Environmental Public Health) since November 21, 2023. The most recent inspection, on September 3, 2026, recorded 1 infraction.

None of the 6 inspections on record were free of infractions. In the past 12 months there were 3 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 8 times across 6 separate inspections, most recently on September 3, 2026. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

6 inspections

  1. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The turnover rate of a whirlpool with a volume more than 4 m3 (1056 USG) is 22 minutes.A recirculation rate shall be maintained so that an amount of water equivalent to 100 percent of the water volume passes through treatment and is recirculated within 20 minutes for a whirlpool with a volume of four or more cubic meters.
  2. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on August 28, 2026, tested positive for Pseudomonas aeruginosa.Treat and resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The turnover rate of a whirlpool with a volume more than 4 m3 (1056 USG) is 22 minutes.A recirculation rate shall be maintained so that an amount of water equivalent to 100 percent of the water volume passes through treatment and is recirculated within 20 minutes for a whirlpool with a volume of four or more cubic meters.
  3. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The turnover rate of a whirlpool with a volume more than 4 m3 (1056 USG) is 22 minutes.A recirculation rate shall be maintained so that an amount of water equivalent to 100 percent of the water volume passes through treatment and is recirculated within 20 minutes for a whirlpool with a volume of four or more cubic meters.
  4. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Repeat violation ** noted on 2022 report.Due to recirculation pump flow rate meter max out the following information were not available.- Flow rate- Turnover period and;- Filtration rate* Flow meter must be replaced with one that can capture higher flow rate.
  5. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample dated March 27 2025 positive for pseudomonas. Please treat, drain, scrub basin, refill, balance, and resample
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Repeat violation ** noted on 2022 report.Due to recirculation pump flow rate meter max out the following information were not available.- Flow rate- Turnover period and;- Filtration rate* Flow meter must be replaced with one that can capture higher flow rate.
  6. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Repeat violation ** noted on 2022 report.Due to recirculation pump flow rate meter max out the following information were not available.- Flow rate- Turnover period and;- Filtration rate* Flow meter must be replaced with one that can capture higher flow rate.