Tality East Village - Cold Plunge 1-2

150 - 606 Confluence Way SE Calgary AB T2G 0G1 · Aquatic Facility

Inspection summary

Tality East Village - Cold Plunge 1-2 has been inspected 6 times by Alberta Health Services (Environmental Public Health) since April 29, 2026. The most recent inspection, on June 18, 2026, found no infractions.

3 of 6 inspections on record found no infractions at all. In the past 12 months there were 6 inspections with 8 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 6 times across 2 separate inspections, most recently on June 11, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times across 2 separate inspections, most recently on June 15, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

6 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The combined chlorine (CC) for tub 1 was: 2.52ppm and 2.43ppm (second test). 2) The combined chlorine (CC) for tub 2 was: 2.44ppm. Please maintain the CC as low as possible to reduce bather irritation. It is recommended to keep the CC below 1.0ppm.
  3. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected from Tub 2 on June 10, 2026, had total coliforms present.-Treat and resample
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected from Tub 2 on June 4, 2026, had total coliforms present.-Treat and resample
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected from Tub 2 on June 4, 2026, had a heterotrophic plate count of 200 CFU/mL.-Resample
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • 1) The free chlorine residual reading in Tub 1 was 0.55 mg/L.2) The free chlorine residual reading in Tub 2 was 0.62 mg/L.-Maintain free chlorine above 1 mg/L. Recommended to aim for 3-5 mg/L
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated reader had an ORP reading of 815 mV, and the set point was at 810 mV, so no chlorine was being added to the system, and therefore not providing adequate chlorine levels.-Set the automated feeding system so that there is adequate chlorine in the system, and recalibrate/clean the probes if necessary/indicated by manufacturer's instructions
  4. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected from Tub 2 on June 4, 2026, had total coliforms present.-Treat and resample
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected from Tub 2 on June 4, 2026, had a heterotrophic plate count of 200 CFU/mL.-Resample
  5. Initial Inspection

    0 infractions

  6. Demand Inspection

    0 infractions