  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 25EN-295E00840 submitted on October 22, 2025, was unsatisfactory: HPC 170.
  3. Monitoring Inspection

    0 infractions

  4. Risk Management Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • A crack was noted in the plaster on the bottom in the middle of the pool. Monitor crack and repair during next pool shut down or if further deterioration occurs.
  5. Monitoring Inspection

    5 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Weirs were missing in the skimmers. Ensure that weirs are provided.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The turnover period was 5.9 hours based on a volume of 15936 gallons and flow rate 45 gpm. The flow was adjusted to 70 gpm during the inspection, resulting in the turnover period 3.79 hours. Please ensure that the turnover period is 4 hours or less.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main drains outlets covers (Hayward WG1032BLV 12*12") expired on November 1, 2023. Replace the main drain outlets.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • A crack was noted in the plaster on the bottom in the middle of the pool. Monitor crack and repair during next pool shut down or if further deterioration occurs.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment compliance plan assessing the entrapment risks had not been developed and was not available for review. Develop a new anti-entrapment compliance plan reflecting the current equipment and submit the plan for review to Environmental Public Health.
  6. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample WE-24-0022194 submitted on March 6, 2024, was unsatisfactory: HPC 110.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • A crack was noted in the plaster on the bottom in the middle of the pool. Monitor crack and repair during next pool shut down or if further deterioration occurs.
  7. Monitoring Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Microbiological water samples have not been submitted for the pool since 14 April 2023. A microbiological water sample was taken onsite. The pool must remain closed until satisfactory results are received.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. Floating weirs were not installed in the skimmer. Weirs were found in the mechanical room and installed by the operator.2. Flow for the pool was low (50 GPM). Operator adjusted bypass for the heater to increase the flow for the system. Flow corrected to 70 GPM.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • A crack was noted in the plaster on the bottom in the middle of the pool. Monitor crack and repair during next pool shut down or if further deterioration occurs.
  8. Risk Management Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Weirs were missing.