Best Western Plus South Edmonton - Swimming Pool
1204 101 Street SW Edmonton AB T6X 0P1 · Aquatic Facility
14 inspections
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Grout holding skimmer lids in place has been cleaned out and skimmer lids are now able to be opened and accessed for cleaning.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter for the pool was unable to be read due to calcium buildup on the exterior as well as calcium inside the unit. GM confirmed replacement flow meters have been ordered and are scheduled to be delivered and installed on January 22.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The skimmer lids appeared to have been grouted and were unable to be removed to access the skimmer. Floating weirs were missing in some of the skimmers and tile debris was noted in a few skimmer baskets. Free the skimmer lids and install working weirs to ensure proper skimming action is occurring.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on [Date] was unsatisfactory: HPC 1290 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow for the swimming pool was 80 GPM. The flow rate through the filter should not exceed 74 GPM. Adjust the flow of the system to between 68-74 GPM
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The Waterway Suction Outlet 640-479x V 9”x9” that expire on February 28, 2025, could not be replaced due to the sump issue identified during the cover replacement.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow for the swimming pool was 80 GPM. The flow rate through the filter should not exceed 74 GPM. Adjust the flow of the system to between 68-74 GPM
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Float in the flow meter was stuck due to debris in the flow meter. Operator noted that it is scheduled for cleaning.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand noted in various corners of the pool basin. Vacuum the basin and investigate cause of sand in basin. Possible causes can be related to lateral damage in the sand filter. Continue to monitor and speak with a service provider to discuss repair options.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Water leaking at the connections to the circulation pump and air bubbling noted in the pool and strainer basket of the pump. Pool operator indicated that the seals require replacement and they are on order. Once installed notify the undersigned and provide confirmation.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on [Date] was unsatisfactory: HPC 2420 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Water leaking at the connections to the circulation pump and air bubbling noted in the pool and strainer basket of the pump. Pool operator indicated that the seals require replacement and they are on order. Once installed notify the undersigned and provide confirmation.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample taken on July 16, 2024 was unsatisfactory. HPC of 2590 CFU/mL. Follow up on the result and confirm water chemistry is satisfactory.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Water leaking at the connections to the circulation pump and air bubbling noted in the pool and strainer basket of the pump. Pool operator indicated that the seals require replacement and they are on order. Once installed notify the undersigned and provide confirmation.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Water leaking at the connections to the circulation pump and air bubbling noted in the pool and strainer basket of the pump. Pool operator indicated that the seals require replacement and they are on order. Once installed notify the undersigned and provide confirmation.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Water leaking at the connections to the circulation pump and air bubbling noted in the pool and strainer basket of the pump. Pool operator indicated that the seals require replacement and they are on order. Once installed notify the undersigned and provide confirmation.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow rate exceeds the max flow of the sand filter. Adjust the flow of the circulation system to less than 75 GPM.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Debris noted in the pool between the main drains. Vacuum the debris in the basin.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
0 infractions