Skip to content
Loading map…

TownePlace Suites Red Deer - Swimming Pool

6822 66 Street Red Deer AB T4P 3T5 · Aquatic Facility

12 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 120.Collected Dec 16, 2025.Chemicals normal.Follow normal sampling procedures.
  3. Monitoring Inspection

    0 infractions

  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    0 infractions

  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results indicate that HPC < = 820 CFU/mL.PHI discussed with Sterling to notify of results. Sterling stated there were no recent changes and pool has not been busy.PHI advised to increase FAC to 10 ppm and maintain pH at or near 7.2. Run the water through the circulation system for at least one turnover, balance the water and resample.
  8. Monitoring Inspection

    0 infractions

  9. Demand Inspection

    0 infractions

  10. Demand Inspection

    0 infractions

  11. Demand Inspection

    0 infractions

  12. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Initial calculations showed a filtration rate of 16gpm/sq.ft. based on a flow rate of 82 gpm and a filtration surface area of 4.91sq.ft.-The CPO reduced the flow rate to 72gpm during the inspection.Therefore the new calculated parameters based on the adjusted flow rate are as follows:-Filtration rate= 14.7gpm/sq.ft-Turnover rate=2.6 hrs.**Ensure the filtration rate for this pool does not exceed 15gpm/sq.ft