  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on Apr. 9, 2026, was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  3. Demand Inspection

    0 infractions

  4. Risk Management Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are several tiles missing in the pool basin.
  5. Monitoring Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free chlorine was measured at 0.04 ppmFree chlorine is required to be at least 1.0 ppm for a swimming pool (temperature less than or equal to 30 C). Alternatively, free chlorine can be at least:a) 0.5 ppm if able to consistently maintain an ORP value of no less than 700 mV, orb) 0.3 ppm if able to consistently maintain an ORP value of no less than 770 mV, a pH of no more than 7.3 and when supplemental disinfection is used.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate was observed to be at 40 GPM.Pool Volume: 10300 GallonsTurnover period: 4.3 hrs A flow rate of at least 43 GPM is required to meet the required turnover period of 4 hours.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are several tiles missing in the pool basin.
  6. Monitoring Inspection

    0 infractions

  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample results collected on 2024-08-15 [ID #: 24EN-228E00683] was unsatisfactory: HPC 5400 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample result submitted on 2024-07-25 was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  11. Risk Management Inspection

    0 infractions

  12. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity: 18ppmMaintain Alkalinity between 60-180ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1-Algal growth was noted on the floor and corners of the basin.
  13. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity: 18ppmMaintain Alkalinity between 60-180ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1-Algal growth was noted on the floor and corners of the basin.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Main drain covers are replaced.Anti-entrapment is required to be updated. Submit an update AE plan for review.
  14. Monitoring Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1-Algal growth was noted on the floor and corners of the basin. 2-Sand accumulation was noted in the corners of the pool.
  15. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was air observed in the pump and in the pool basin indicating leakage in the system. Investigate and fix it. Operator informed PHIs that automated aquatics are working on it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily visual checks of main drain covers were not being done and recorded. Discussed with operator onsite and advise to do a visual check daily and keep record with other chemical parameters.
  16. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample result submitted on 2nd April 2024 [Accession #: WE-24-0030652] was unsatisfactory. HPC ;250CFU/ml.Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was air observed in the pump and in the pool basin indicating leakage in the system. Investigate and fix it. Operator informed PHIs that automated aquatics are working on it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily visual checks of main drain covers were not being done and recorded. Discussed with operator onsite and advise to do a visual check daily and keep record with other chemical parameters.
  17. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was air observed in the pump and in the pool basin indicating leakage in the system. Investigate and fix it. Operator informed PHIs that automated aquatics are working on it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily visual checks of main drain covers were not being done and recorded. Discussed with operator onsite and advise to do a visual check daily and keep record with other chemical parameters.
  18. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample result submitted on 2023-11-30 [Accession #: WE-23-0128572] was unsatisfactory. HPC 610 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was air observed in the pump and in the pool basin indicating leakage in the system. Investigate and fix it. Operator informed PHIs that automated aquatics are working on it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily visual checks of main drain covers were not being done and recorded. Discussed with operator onsite and advise to do a visual check daily and keep record with other chemical parameters.
  19. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was air observed in the pump and in the pool basin indicating leakage in the system. Investigate and fix it. Operator informed PHIs that automated aquatics are working on it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily visual checks of main drain covers were not being done and recorded. Discussed with operator onsite and advise to do a visual check daily and keep record with other chemical parameters.
  20. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine residual is not being maintained at the lowest level possible to maximize bather comfort. Ensure combined chlorine is maintained less than 1 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Sand accumulation was noted throughout the basin.Investigate the reasons for sand accumulation in the pool basin and maintain the pool in a clean and sanitary condition.