130 Ebony Boulevard - Swimming Pool

130 Ebony Boulevard Sherwood Park AB T8H 0L2 · Aquatic Facility

Inspection summary

130 Ebony Boulevard - Swimming Pool has been inspected 31 times by Alberta Health Services (Environmental Public Health) since June 3, 2024. The most recent inspection, on September 14, 2026, found no infractions.

8 of 31 inspections on record found no infractions at all. In the past 12 months there were 7 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Chemicals and toxic substances and Food temperature control.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 28 times across 22 separate inspections, most recently on August 31, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 4 times across 4 separate inspections, most recently on May 28, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 2 times across 2 separate inspections, most recently on June 10, 2024. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 5 times across 5 separate inspections, most recently on September 20, 2024. For example: Are proper testing, monitoring, and other records being properly maintained?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 2 times across 2 separate inspections, most recently on June 10, 2024. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

31 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was 1890 on the lab report. Remediate and resample.
  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was 120 on the lab report. Remediate and resample.
  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was 120 on the lab report. Remediate and resample.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was 190 on the lab report. Remediate and resample.
  7. Monitoring Inspection

    0 infractions

  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from water sample collected September 16 2025 indicate a Heterotrophic plate Count of 110 CFU/mL.Resample requested.
  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from water sample collected August 7, 2025 indicate a Heterotrophic plate Count of 880 CFU/mL.Resample requested.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken July 10, 2025 showed a HPC of 1570 CFU/mL.Operator requested to treat and resample.Results from sample taken July 15, 2025 showed a HPC of 190 CFU/mL.Operator requested to treat and resample.Results from sample Taken July 22 showed a HPC of 320 CFU/mL.Operator to close pool until inspection occurs and satisfactory water sample result is received.
  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken June 10, 2025 showed a HPC of 1570 CFU/mL.Operator requested to treat and resample.Results from sample taken July 15, 2025 showed a HPC of 190 CFU/mL.Operator requested to treat and resample.
  14. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken July 10, 2025 showed a HPC of 390 CFU/mL.Operator requested to treat and resample.Results from sample taken July 15, 2025 showed a HPC of 190 CFU/mL.Operator requested to treat and resample.
  15. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken June 10, 2025 showed a HPC of 1570 CFU/mL.Operator requested to treat and resample.
  16. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken June 10, 2025 showed a HPC of 730 CFU/mL.
  17. Risk Management Inspection

    0 infractions

  18. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free Available Chlorine measured 0.12 ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller indicated pH of pool was 7.2, while manual readings found the pH to be 7.6
  19. Risk Management Inspection

    0 infractions

  20. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 140- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced. The pool will remain closed until a satisfactory sample will be received.
  21. Risk Management Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total coliforms present
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced. The will remain closed until a satisfactory sample will be received.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  22. Risk Management Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced. The will remain closed until a satisfactory sample will be received.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  23. Risk Management Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total coliform present
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  24. Monitoring Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Collection Date: 2024-08-15** Heterotrophic Plate Count: 1740 CFU/mL - The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  25. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • CYA 57
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Manual chemistry records are not maintained every day as per the requirements. Ensure adequate records are maintained as work/readings is completed.
  26. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • High HPC count (700)
  27. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • High HPC count (740).
  28. Risk Management Inspection

    0 infractions

  29. Risk Management Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • OR readingpH 7.7
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • *Alarm light was illuminated on the controller and a low ORP (around 276 mV). Investigate and make adjustments as required to ensure chlorine generation system in good working order.
  30. Risk Management Inspection

    4 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FC 0.22
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • *Alarm light was illuminated on the controller and a low ORP (around 276 mV). Investigate and make adjustments as required to ensure chlorine generation system in good working order.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • *Debris were observed in the pool basin. Remove and vacuum the basin to remove debris and dirt.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • *Anti-entrapment plan for the pool not in place. A plan with pool information was submitted; however, the plan does not appear to be match the pool's mechanical drawing information.
  31. Initial Inspection

    3 infractions

    • 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
      • *No flow was observed at the flow meter level.*Alarm light was illuminated on the controller and a low ORP (around 230 mV). Investigate and make adjustments as required to ensure chlorine generation system in good working order.*Cavitation like noise was observed for the pump.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • *Large debris had blown into the pool basin. Remove and vacuum the basin to remove debris and dirt.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • *Anti-entrapment plan for the pool not in place. A plan with pool information was submitted; however, the plan does not appear to be match the pool's mechanical drawing information.