18012 95 Avenue NW - Swimming Pool
18012 95 Avenue NW Edmonton AB T5T 5Z2 · Aquatic Facility
Inspection summary
18012 95 Avenue NW - Swimming Pool has been inspected 3 times by Alberta Health Services (Environmental Public Health) since March 20, 2025. The most recent inspection, on January 23, 2026, recorded 1 infraction.
1 of 3 inspections on record found no infractions at all. In the past 12 months there was 1 inspection with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 2 times across 2 separate inspections, most recently on January 23, 2026. For example:
Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded once on March 20, 2025. For example:
Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
3 inspections
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate was observed to be at 67 GPM.Pool Volume: 10300 GallonsFilter area: 3.1 sq ftThe filtration rate was calculated to be at 21.6 gpm/sq ft, which exceeds the maximum of 15 gpm/sq ft.Corrective Action:- The pool operator decreased the flow rate to 45 GPM during the inspection.- The filtration rate was calculated to be at 14.5 gpm/sq ft, which is below the maximum of 15 gpm/sq ft.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was 26ppm. Chemical added manually to increase thel alkalinity by the pool operator during the inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Filtration rate was 26.98gpm/ft2. Lower the flow rate to 60gpm to ensure the filtration rate does not exceed the maximum of 20gpm/ft2 as per manufacturer's specifications.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
Nearby inspected facilities
- 18012 95 Avenue NW - Pool Premise Common Area
18012 95 Avenue NW Edmonton AB T5T 5Z2
2 inspections
- 18012 95 Avenue NW - Whirlpool
18012 95 Avenue NW Edmonton AB T5T 5Z2
5 inspections
- H2H Spa
101 - 10510 180 STREET NW Edmonton AB T5S 2P1
3 inspections
- St. Benedict School--Nutrition Program
18015 93 Avenue NW Edmonton AB T5T 1X5
2 inspections
- Belmead Community League
9109 182 Street NW Edmonton AB T5T 2Y9
1 inspection
- Miss Beauty
9642 182 Street NW Edmonton AB T5T 3N4
4 inspections
- Belmead School - E4C Nutrition Program
9011 182 Street NW Edmonton AB T5T 2Y9
1 inspection
- Belmead Elementary School--Nutrition Program
9011 182 Street NW Edmonton AB T5T 2Y9
1 inspection