612 111 Street SW - Swimming Pool
612 111 Street SW Edmonton AB T6W 1R9 · Aquatic Facility
5 inspections
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was 48 ppm. Ensure that total alkalinity is maintained between 60 and 180 ppm. Updated on June 23, 2026:* Total alkalinity was 42 ppm. Ensure that total alkalinity is maintained between 60 and 180 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There was a discrepancy between the automated controller reading for pH 6.94 and the manual reading pH 7.48. Updated on June 10, 2026:* There was a discrepancy between the automated controller reading for pH 7.14 and the manual reading pH 7.44 (from the automated controller). Updated on June 23, 2026:* There was a discrepancy between the automated controller reading for pH 6.99 and the manual reading pH 7.38 (PHI) and 7.35 (operator) (from the automated controller).
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
3 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was 48 ppm. Ensure that total alkalinity is maintained between 60 and 180 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There was a discrepancy between the automated controller reading for pH 6.94 and the manual reading pH 7.48. Updated on June 10, 2026:* There was a discrepancy between the automated controller reading for pH 7.14 and the manual reading pH 7.44 (from the automated controller).
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- The pool water temperature was over 30C (system reading 30.7C, and manual reading about 30.1C). Ensure that the temperature is maintained under 30C, or request the testing for Pseudomonas aeruginosa on the requisition form for the water samples, as required for pools maintained over 30C.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There was a discrepancy between the automated controller reading for pH 6.94 and the manual reading pH 7.48.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There was a discrepancy between the automated controller reading for pH 6.94 and the manual reading pH 7.48.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Hayward 9x9 covers, installed on January 5, 2023, expire on January 5, 2030, were reported (according to the email note received on February 2, 2023), but no updated Anti-Entrapment Compliance Plan was submitted. Please update the plan and submit an updated version to our office.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- There was a discrepancy between the automated controller reading for pH 6.83 and the manual reading pH 7.48. It was addressed during hte inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Rate of filtration for the filtration system was 16.32 gpm/sq ft based on a filtration area of 4.91 sq ft and flow rate 80 gpm. The flow rate was lowered to 70 gpm during the inspection, which resulted in rate of filtration 14.29 gpm/ sq ft (acceptable).
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?