Best Western Plus The Inn at St. Albert - Whirlpool

460 St. Albert Trail St. Albert AB T8N 5J9 · Aquatic Facility

32 inspections

  1. Demand Inspection

    7 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas was isolated in the most recent bacteriological sample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir is missing in the NW corner. The SE weir has some visual scum accumulation.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The SE jet is missing the directional fitting.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There is air entering into the circulation pump/filter. Bubbles were observed rising in the whirlpool with jets off. Air was bled from the filter gauge and returned, so there may be a leak.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Despite records showing inadequate levels of chlorine on multiple days, actions were not taken and if they were, they were not recorded. No additional testing was done or records written to show is corrective actions were effective.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are some areas of missing grout and/or caulking within the basin.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record showed large gaps where testing was not occurring. Testing must be occurring daily and any actions taken must be subsequently recorded.
  2. Risk Management Inspection

    6 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir is missing in the NW corner. The SE weir has some visual scum accumulation.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The SE jet is missing the directional fitting.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There is air entering into the circulation pump/filter. Bubbles were observed rising in the whirlpool with jets off. Air was bled from the filter gauge and returned, so there may be a leak.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Despite records showing inadequate levels of chlorine on multiple days, actions were not taken and if they were, they were not recorded. No additional testing was done or records written to show is corrective actions were effective.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are some areas of missing grout and/or caulking within the basin.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record showed large gaps where testing was not occurring. Testing must be occurring daily and any actions taken must be subsequently recorded.
  3. Demand Inspection

    7 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • May 11, 2026: Pseudomonas aeruginosa was present in the most recent bacteriological water sample, taken May 6, 2026.April 6, 2026: Pseudomonas aeruginosa was present in the most recent bacteriological water sample, taken April 4, 2026.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir is missing in the NW corner. The SE weir has some visual scum accumulation.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The SE jet is missing the directional fitting.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There is air entering into the circulation pump/filter. Bubbles were observed rising in the whirlpool with jets off. Air was bled from the filter gauge and returned, so there may be a leak.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Despite records showing inadequate levels of chlorine on multiple days, actions were not taken and if they were, they were not recorded. No additional testing was done or records written to show is corrective actions were effective.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are some areas of missing grout and/or caulking within the basin.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record showed large gaps where testing was not occurring. Testing must be occurring daily and any actions taken must be subsequently recorded.
  4. Risk Management Inspection

    7 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was present in the most recent bacteriological water sample, taken April 4, 2026.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir is missing in the NW corner. The SE weir has some visual scum accumulation.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The SE jet is missing the directional fitting.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There is air entering into the circulation pump/filter. Bubbles were observed rising in the whirlpool with jets off. Air was bled from the filter gauge and returned, so there may be a leak.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Despite records showing inadequate levels of chlorine on multiple days, actions were not taken and if they were, they were not recorded. No additional testing was done or records written to show is corrective actions were effective.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are some areas of missing grout and/or caulking within the basin.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record showed large gaps where testing was not occurring. Testing must be occurring daily and any actions taken must be subsequently recorded.
  5. Demand Inspection

    8 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was present in the most recent bacteriological water sample, taken April 4, 2026.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir is missing in the NW corner. The SE weir has some visual scum accumulation.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The SE jet is missing the directional fitting.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There is air entering into the circulation pump/filter. Bubbles were observed rising in the whirlpool with jets off. Air was bled from the filter gauge and returned, so there may be a leak.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Despite records showing inadequate levels of chlorine on multiple days, actions were not taken and if they were, they were not recorded. No additional testing was done or records written to show is corrective actions were effective.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are some areas of missing grout and/or caulking within the basin.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Proof of registration for pool certification course is required.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record showed large gaps where testing was not occurring. Testing must be occurring daily and any actions taken must be subsequently recorded.
  6. Risk Management Inspection

    7 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir is missing in the NW corner. The SE weir has some visual scum accumulation.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The SE jet is missing the directional fitting.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There is air entering into the circulation pump/filter. Bubbles were observed rising in the whirlpool with jets off. Air was bled from the filter gauge and returned, so there may be a leak.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Despite records showing inadequate levels of chlorine on multiple days, actions were not taken and if they were, they were not recorded. No additional testing was done or records written to show is corrective actions were effective.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are some areas of missing grout and/or caulking within the basin.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Proof of registration for pool certification course is required.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record showed large gaps where testing was not occurring. Testing must be occurring daily and any actions taken must be subsequently recorded.
  7. Monitoring Inspection

    8 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample taken October 15, 2025, had Pseudomonas present.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The SE jet is missing the directional fitting.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There is air entering into the circulation pump/filter. Bubbles were observed rising in the whirlpool with jets off. Air was bled from the filter gauge and returned, so there may be a leak.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The floating weir is missing in the NW corner. The SE weir has some visual scum accumulation.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Despite records showing inadequate levels of chlorine on multiple days, actions were not taken and if they were, they were not recorded. No additional testing was done or records written to show is corrective actions were effective.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are some areas of missing grout and/or caulking within the basin.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Proof of registration for pool certification course is required.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record showed large gaps where testing was not occurring. Testing must be occurring daily and any actions taken must be subsequently recorded.
  8. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample taken October 15, 2025, had Pseudomonas present.
  9. Risk Management Inspection

    0 infractions

  10. Risk Management Inspection

    4 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH was <6.5 - 6.94.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FAC was 0.29 ppm.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was 2 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • A Leak was observed on piping near whirlpool flow meter in mechanical room.
  11. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • September 15, 2025: Pseudomonas aeruginosa was isolated in the sample taken September 9, 2025.September 8, 2025: Pseudomonas aeruginosa was isolated in the sample taken September 3, 2025.August 29, 2025: Pseudomonas aeruginosa was isolated in the sample taken August 27, 2025.August 11, 2025: Pseudomonas aeruginosa was present in the sample taken August 6, 2025.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was calculated over 57000 CFU/mL in the sample taken on September 9, 2025.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine levels for the whirlpool were tested using dilution method and were found to be at 11.32 ppm, with total and combined chlorines unknown. Pool records showed this has been a regular occurrence over the last few weeks. Address underlying issue either with topping up chlorine shock manually or salt cell generation. Reduce total chlorine level below 10 ppm at a minimum, and preferably in the 2-4 ppm range.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Floating weir nearest shower does not appear to be functioning properly. Weir basket has a buildup of scum floating inside of it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Accurate records are not being kept of any chemicals added or treatments performed for the pool.
  12. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • September 8, 2025: Pseudomonas aeruginosa was isolated in the sample taken September 3, 2025.August 29, 2025: Pseudomonas aeruginosa was isolated in the sample taken August 27, 2025.August 11, 2025: Pseudomonas aeruginosa was present in the sample taken August 6, 2025.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine levels for the whirlpool were tested using dilution method and were found to be at 11.32 ppm, with total and combined chlorines unknown. Pool records showed this has been a regular occurrence over the last few weeks. Address underlying issue either with topping up chlorine shock manually or salt cell generation. Reduce total chlorine level below 10 ppm at a minimum, and preferably in the 2-4 ppm range.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Floating weir nearest shower does not appear to be functioning properly. Weir basket has a buildup of scum floating inside of it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Accurate records are not being kept of any chemicals added or treatments performed for the pool.
  13. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • September 8, 2025: Pseudomonas aeruginosa was isolated in the sample taken September 3, 2025.August 29, 2025: Pseudomonas aeruginosa was isolated in the sample taken August 27, 2025.August 11, 2025: Pseudomonas aeruginosa was present in the sample taken August 6, 2025.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter for the whirlpool was not in good working condition.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • September 8, 2025: This issue remains ongoing as per records. June 19th, 2025: Free chlorine levels for the whirlpool were tested using dilution method and were found to be at 11.32 ppm, with total and combined chlorines unknown. Pool records showed this has been a regular occurrence over the last few weeks. Address underlying issue either with topping up chlorine shock manually or salt cell generation. Reduce total chlorine level below 10 ppm at a minimum, and preferably in the 2-4 ppm range.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • September 8, 2025: Not observedJune 19th, 2025: Floating weir nearest shower does not appear to be functioning properly. Weir basket has a buildup of scum floating inside of it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • September 8 2025: Ongoing issue. Template sent for records. June 19 2025: Accurate records are not being kept of any chemicals added or treatments performed for the pool.
  14. Demand Inspection

    6 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • August 29, 2025: Pseudomonas aeruginosa was isolated in the sample taken August 27, 2025.August 11, 2025: Pseudomonas aeruginosa was present in the sample taken August 6, 2025.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • August 29, 2025: HPC was >57000 cfu for the sample taken August 27 2025August 11, 2025: HPC was 830 cfu for the sample taken August 6 2025
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine levels are not being kept as slow as possible as chlorine levels are consistently above testing equipment's parameters and thus CC cannot be calculated.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine levels for the whirlpool were tested using dilution method and were found to be at 11.32 ppm, with total and combined chlorines unknown. Pool records showed this has been a regular occurrence over the last few weeks. Address underlying issue either with topping up chlorine shock manually or salt cell generation. Reduce total chlorine level below 10 ppm at a minimum, and preferably in the 2-4 ppm range.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Floating weir nearest shower does not appear to be functioning properly. Weir basket has a buildup of scum floating inside of it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Accurate records are not being kept of any chemicals added or treatments performed for the pool.
  15. Demand Inspection

    6 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was present in the sample taken August 6 2025.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC was 830 cfu for the sample taken August 6 2025
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine levels are not being kept as slow as possible as chlorine levels are consistently above testing equipment's parameters and thus CC cannot be calculated.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine levels for the whirlpool were tested using dilution method and were found to be at 11.32 ppm, with total and combined chlorines unknown. Pool records showed this has been a regular occurrence over the last few weeks. Address underlying issue either with topping up chlorine shock manually or salt cell generation. Reduce total chlorine level below 10 ppm at a minimum, and preferably in the 2-4 ppm range.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Floating weir nearest shower does not appear to be functioning properly. Weir basket has a buildup of scum floating inside of it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Accurate records are not being kept of any chemicals added or treatments performed for the pool.
  16. Demand Inspection

    5 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC were calculated >57000 CFU/mL.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine levels are not being kept as slow as possible as chlorine levels are consistently above testing equipment's parameters and thus CC cannot be calculated.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine levels for the whirlpool were tested using dilution method and were found to be at 11.32 ppm, with total and combined chlorines unknown. Pool records showed this has been a regular occurrence over the last few weeks. Address underlying issue either with topping up chlorine shock manually or salt cell generation. Reduce total chlorine level below 10 ppm at a minimum, and preferably in the 2-4 ppm range.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Floating weir nearest shower does not appear to be functioning properly. Weir basket has a buildup of scum floating inside of it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Accurate records are not being kept of any chemicals added or treatments performed for the pool.
  17. Monitoring Inspection

    4 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine levels are not being kept as slow as possible as chlorine levels are consistently above testing equipment's parameters and thus CC cannot be calculated.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Free chlorine levels for the whirlpool were tested using dilution method and were found to be at 11.32 ppm, with total and combined chlorines unknown. Pool records showed this has been a regular occurrence over the last few weeks. Address underlying issue either with topping up chlorine shock manually or salt cell generation. Reduce total chlorine level below 10 ppm at a minimum, and preferably in the 2-4 ppm range.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Floating weir nearest shower does not appear to be functioning properly. Weir basket has a buildup of scum floating inside of it.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Accurate records are not being kept of any chemicals added or treatments performed for the pool.
  18. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated from the sample taken May 28, 2025.
  19. Risk Management Inspection

    0 infractions

  20. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An anti-entrapment plan for the whirlpool basin has not been submitted for review.
  21. Demand Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Filter rate was calculated at 14.87 GPM/SF. (105 GPM flow rate / 7.06 SF filter area = 14.87 GPM/SF).
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The flow gauge for the whirlpool is nonfunctional.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An anti-entrapment plan for the whirlpool basin has not been submitted for review.
  22. Monitoring Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FAC was tested and found to be at 1.07. Pool operator increased chlorine toward end of inspection.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was tested and found to be at 0. Pool operator manually adjusted toward end of inspection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Filter rate was calculated at 14.87 GPM/SF. (105 GPM flow rate / 7.06 SF filter area = 14.87 GPM/SF).
  23. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC for the sample taken September 4 2024 was 530.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated controller readings were not in consistent with the readings by PHI and chemical logs of manual testing observed in the facility, had a difference of greater that 0.2.Make sure that automated controller systems are calibrated to ensure the accuracy of testing.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • The alkalinity reagent used for water testing was expired.Make sure that reagents used for water testing are not expired, to ensure the adequate testing of water.
  24. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated controller readings were not in consistent with the readings by PHI and chemical logs of manual testing observed in the facility, had a difference of greater that 0.2.Make sure that automated controller systems are calibrated to ensure the accuracy of testing.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • The alkalinity reagent used for water testing was expired.Make sure that reagents used for water testing are not expired, to ensure the adequate testing of water.
  25. Risk Management Inspection

    0 infractions

  26. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The tested level of FAC in the hot tub was 1.85, below the required 2.0 for a basin above 30C.
  27. Risk Management Inspection

    0 infractions

  28. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated in a sample taken November 15 2023.
  29. Risk Management Inspection

    0 infractions

  30. Monitoring Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated from a sample taken August 2 2023 and a subsequent resample taken August 14 2023 following superchlorination.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • A sample was not submitted for the previous week. Ensure samples are collected and submitted weekly.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Records were not being satisfactorily kept for chemical additions to the basin. No record of the shock treatment was available, nor any record of what days the basin was closed for treatment.
  31. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated from a sample taken August 2 2023 and a subsequent resample taken August 14 2023 following superchlorination.
  32. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated from a sample taken August 2 2023.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC counts for a sample taken August 2 2023 were 850 CFU/mL.