Calgary Airport Marriott Hotel - Whirlpool

2008 Airport Road NE Calgary AB T2E 3B9 · Aquatic Facility

10 inspections

  1. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The free chlorine measured 1.25 ppm. - Operator raised the chlorine to 2.02 ppm during inspection.**Ensure free chlorine is maintained at 2 ppm or above at all times.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine measured 2.77 ppm. **Ensure combined chlorine is maintained as low as possible.
  2. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on April 9, 2025 was not tested due to the Date/Time of sample collection is LATER than the Date/Time of receipt.Please resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The total alkalinity was measured to be 54 ppm.REQUIREMENT: Maintain the total alkalinity between 60 - 180 ppm.2) The combined chlorines were measured to be 3.58 ppm.REQUIREMENT: Maintain the combined chlorines to the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • MARCH 20, Confirmation of Pool Volume at 1398 US Gallons. REPEAT VIOLATION- FIRST NOTED JUNE 2024. Filter must be replaced or additional filter added to ensure minimum flow rates and required turnover are met. Must be completed by April 30, 2025. or further enforcement action will be taken. The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (
  3. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The total alkalinity was measured to be 54 ppm.REQUIREMENT: Maintain the total alkalinity between 60 - 180 ppm.2) The combined chlorines were measured to be 3.58 ppm.REQUIREMENT: Maintain the combined chlorines to the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • MARCH 20, Confirmation of Pool Volume at 1398 US Gallons. REPEAT VIOLATION- FIRST NOTED JUNE 2024. Filter must be replaced or additional filter added to ensure minimum flow rates and required turnover are met. Must be completed by April 30, 2025. or further enforcement action will be taken. The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (
  4. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The total alkalinity was measured to be 54 ppm.REQUIREMENT: Maintain the total alkalinity between 60 - 180 ppm.2) The combined chlorines were measured to be 3.58 ppm.REQUIREMENT: Maintain the combined chlorines to the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1) The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (> 5.6 sq.ft)2) The current flow meter for the system does not allow for accurate readings of the flow (minimum is 100 USGPM) which would greatly exceed the maximum rate of filtration. REQUIREMENT: Install a new flow meter which shows the ranges of 40-110 USGPM.
  5. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The total alkalinity was measured to be 54 ppm.REQUIREMENT: Maintain the total alkalinity between 60 - 180 ppm.2) The combined chlorines were measured to be 3.58 ppm.REQUIREMENT: Maintain the combined chlorines to the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1) The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (> 5.6 sq.ft)2) The current flow meter for the system does not allow for accurate readings of the flow (minimum is 100 USGPM) which would greatly exceed the maximum rate of filtration. REQUIREMENT: Install a new flow meter which shows the ranges of 40-110 USGPM.
  6. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on October 09, 2024, had Pseudomonas isolated in the sample.REQUIREMENT: Begin treatment for the whirlpool immediately. Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The total alkalinity was measured to be 54 ppm.REQUIREMENT: Maintain the total alkalinity between 60 - 180 ppm.2) The combined chlorines were measured to be 3.58 ppm.REQUIREMENT: Maintain the combined chlorines to the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1) The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (> 5.6 sq.ft)2) The current flow meter for the system does not allow for accurate readings of the flow (minimum is 100 USGPM) which would greatly exceed the maximum rate of filtration. REQUIREMENT: Install a new flow meter which shows the ranges of 40-110 USGPM.
  7. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on August 07, 2024, had Pseudomonas isolated in the sample.REQUIREMENT: Begin treatment for the whirlpool immediately. Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on August 07, 2024, had Pan HPC count of 1080 CFU/mL.REQUIREMENT: Begin treatment for the whirlpool. Submit a re-sample after you complete necessary treatments and the water chemistry is rebalanced.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The total alkalinity was measured to be 54 ppm.REQUIREMENT: Maintain the total alkalinity between 60 - 180 ppm.2) The combined chlorines were measured to be 3.58 ppm.REQUIREMENT: Maintain the combined chlorines to the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1) The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (> 5.6 sq.ft)2) The current flow meter for the system does not allow for accurate readings of the flow (minimum is 100 USGPM) which would greatly exceed the maximum rate of filtration. REQUIREMENT: Install a new flow meter which shows the ranges of 40-110 USGPM.
  8. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1) The total alkalinity was measured to be 54 ppm.REQUIREMENT: Maintain the total alkalinity between 60 - 180 ppm.2) The combined chlorines were measured to be 3.58 ppm.REQUIREMENT: Maintain the combined chlorines to the lowest level possible.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1) The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (> 5.6 sq.ft)2) The current flow meter for the system does not allow for accurate readings of the flow (minimum is 100 USGPM) which would greatly exceed the maximum rate of filtration. REQUIREMENT: Install a new flow meter which shows the ranges of 40-110 USGPM.
  9. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1) The whirlpool originally was designed with a cartridge filter. However, this was replaced with a High Rate Sand Filter (1 Triton TR-100C Sand Filter) which does not have sufficient square footage to allow for the turnover and maximum rate of filtration to both be compliant.REQUIREMENT: Operator must replace this sand filter and install a new sand filter which has a minimum sufficient square footage (> 5.6 sq.ft)2) The current flow meter for the system does not allow for accurate readings of the flow (minimum is 100 USGPM) which would greatly exceed the maximum rate of filtration. REQUIREMENT: Install a new flow meter which shows the ranges of 40-110 USGPM.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Ongoing Violation** Automated system readings were inconsistent with manual tests for pH.- Adjust/calibrate as required.
  10. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • 1. pH measured 7.78- Ensure pH is maintained between 6.8-7.6. Sherpa adjusted pH set points during inspection, will retest in 1-2 turnovers to ensure pH is within range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. Automated system readings were inconsistent with manual tests for pH.- Adjust/calibrate as required.2. Filtration rate was 16gpm/ft2.- Filtration rate cannot exceed 12.5gpm/ft2. Note: if adjusting flow, turnover rate must be at least 15 min.