Canalta St. Paul - Main Pool
5008 43 Street St. Paul AB T0A 3A2 · Aquatic Facility
13 inspections
- Monitoring Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Calculated turn over period is inadequate (6 hr). High turnover period causes pollution build-up in pool.Please fix the pool circulation system and ensure pool turn over around 4 hr.*Repeated violation 12/5/25
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample 24EN-332E00408 has an HPC 340 CFU/mL. This could indicate a failure of the disinfection system. Please check the pools chemistry and ensure they are all within the acceptable parameters.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- PH is at 6.7. Low PH causes eye irritation, dry skin and irritation to swimmers. It also corrodes metal surfaces and pool accessories.Please adjust PH value within the range of 6.8 to 7.6
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Calculated turn over period is inadequate (6 hr). High turnover period causes pollution build-up in pool.Please fix the pool circulation system and ensure pool turn over around 4 hr.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 260 CFU/mL.Follow steps as per email shared.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- PH is at 6.7. Low PH causes eye irritation, dry skin and irritation to swimmers. It also corrodes metal surfaces and pool accessories.Please adjust PH value within the range of 6.8 to 7.6
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Calculated turn over period is inadequate (6 hr). High turnover period causes pollution build-up in pool.Please fix the pool circulation system and ensure pool turn over around 4 hr.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 260 CFU/mL.Follow steps as per email shared.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC >57000 CFU/mL
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC >57000 CFU/mL
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC is at 130 CFU/mLHPC should be no greater than 100 CFU/mL
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC is at 130 CFU/mLHPC should be no greater than 100 CFU/mL
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions