Chateaux On The Green - Whirlpool
1825 Varsity Estates Drive NW Calgary AB T3B 3Y7 · Aquatic Facility
6 inspections
- Monitoring Inspection
0 infractions
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The maximum filtration rate of the high rate sand filter is calculated at 14.7USG/M/ft^2.*Lower the flow rate to maintain the maximum filtration rate to 12.5 USG/M/ft^2
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The maximum filtration rate of the high rate sand filter is calculated at 14.9 USG/M/ft^2.*Lower the flow rate to maintain the maximum filtration rate to 12.5 USG/M/ft^2*****This is a repeated violation
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample not processed- no identification number listed
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The maximum filtration rate of the high rate sand filter is calculated at 14.7USG/M/ft^2.*Lower the flow rate to maintain the maximum filtration rate to 12.5 USG/M/ft^2
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The maximum filtration rate of the high rate sand filter is calculated at 14.9 USG/M/ft^2.*Lower the flow rate to maintain the maximum filtration rate to 12.5 USG/M/ft^2*****This is a repeated violation
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Seal the area around the hot tub.Replace the expired drain covers.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The maximum filtration rate of the high rate sand filter is calculated at 14.7USG/M/ft^2.*Lower the flow rate to maintain the maximum filtration rate to 12.5 USG/M/ft^2
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The maximum filtration rate of the high rate sand filter is calculated at 14.9 USG/M/ft^2.*Lower the flow rate to maintain the maximum filtration rate to 12.5 USG/M/ft^2*****This is a repeated violation
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Seal the area around the hot tub.Replace the expired drain covers.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?