Comfort Inn & Suites - Whirlpool

4611 Macleod Trail SW Calgary AB T2G 0A6 · Aquatic Facility

8 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on March 13, 2026, had HPC 290 cfu/ml.Advised to resample.
  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on December 12, 2025 was not processed as it was received at the lab on December 13, 2025 (a Saturday).
  4. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • No anti-entrapment plan was available.- Provide the anti-entrapment plan for review.
  5. Monitoring Inspection

    5 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Manual pH testing of the whirlpool water showed pH very low, at 6.56.- Maintain pH between 6.8-7.6.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine level tested over 2 ppm and chorine smell was present in the indoor air as well. - Maintain combined chlorine at the lowest level possible. - Add fresh water more often to keep the combined chlorine low.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated monitoring system’s chemical readings were inconsistent with manual testing. Automated reading for pH was 7.3 and manual testing was 6.56. - Clean the probes and calibrate the system so it is providing consistent reading with manual testing.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Whirlpool water temperature measured at 43C. - Water temperature must be maintained at 40C or lower.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • No anti-entrapment plan was available.- Provide the anti-entrapment plan for review.
  6. Monitoring Inspection

    0 infractions

  7. Risk Management Inspection

    5 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity of the whirlpool was 52 ppm. Please ensure the total alkalinity is 60-180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter for the hot tub is not working. Please replace.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • REPEAT VIOLATIONS: 1. Pool chemistry testing results are not recorded daily. Every Sunday the log is blank (as of January 2022). Other sporadic days are also blank. The pool is open for use on Sundays. 2. The inspection results for the submerged suction outlet covers are not recorded daily. Every Sunday the log is blank (as of January 2022). Other sporadic days are also blank. COMPLETE THE FOLLOWING: 1. The pool chemistry must be tested on days when the pool is open for public use. Ensure the results are recorded daily. 2. The submerged suction outlet covers must be inspected prior to the pool opening daily. Ensure the results are recorded daily. 3. Replace the empty or expired reagents.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • REPEAT VIOLATION: - An anti-entrapment plan has been submitted, but clarification is still required. COMPLETE THE FOLLOWING: - Provide additional information regarding the anti-entrapment plan. Refer to the email previous sent.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • REPEAT VIOLATION:- Written procedure is incomplete. Written procedure for treatment of water after identifying pseudomonas in the water is not available. COMPLETE THE FOLLOWING: - Ensure written policies for the above is available.
  8. Demand Inspection

    6 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample collected and analyzed on 2023-08-10 shows the presence of pseudomonas.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity of the whirlpool was 52 ppm. Please ensure the total alkalinity is 60-180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter for the hot tub is not working. Please replace.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • REPEAT VIOLATIONS: 1. Pool chemistry testing results are not recorded daily. Every Sunday the log is blank (as of January 2022). Other sporadic days are also blank. The pool is open for use on Sundays. 2. The inspection results for the submerged suction outlet covers are not recorded daily. Every Sunday the log is blank (as of January 2022). Other sporadic days are also blank. COMPLETE THE FOLLOWING: 1. The pool chemistry must be tested on days when the pool is open for public use. Ensure the results are recorded daily. 2. The submerged suction outlet covers must be inspected prior to the pool opening daily. Ensure the results are recorded daily. 3. Replace the empty or expired reagents.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • REPEAT VIOLATION: - An anti-entrapment plan has been submitted, but clarification is still required. COMPLETE THE FOLLOWING: - Provide additional information regarding the anti-entrapment plan. Refer to the email previous sent.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • REPEAT VIOLATION:- Written procedure is incomplete. Written procedure for treatment of water after identifying pseudomonas in the water is not available. COMPLETE THE FOLLOWING: - Ensure written policies for the above is available.