Courtyard & Residence Inn by Marriott Calgary Airport - Pool
2500 48 Avenue NE Calgary AB T3J 4V8 · Aquatic Facility
32 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 2020Sample ID 26ES015E00131Sample collection date 15 Jan 2026Resampling advised
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- ID 25ES-268E00200Pool greater than 30CPseudomonas Aeruginosa isolatedTreatment and water sample advised.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- ID 25ES-268E00200Pool greater than 30CPseudomonas Aeruginosa isolatedTreatment and water sample advised.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on August 28, 2025, was unsatisfactory with an HPC of 130 CFU/mL. Please submit another sample for re-testing.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on August 7, 2025, was unsatisfactory with an HPC of 1,940 CFU/mL. Please submit another sample for re-assessment.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A water sample collected on June 26, 2025, was not tested as time of collection was not indicated.**Please re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on June 12, 2025, had an HPC of 110 CFU/mL.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on April 3, 2025, had an HPC of 110 CFU/mL.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on January 02, 2025, had an HPC of 160 CFU/mL in the sample. Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.**OUTSTANDING (2025-02-06). The water sample collected on February 6, 2025, had an HPC of 320 CFU/mL. Initiate treatment of the pool. Send a resample after all the necessary treatments is completed and when the water chemistry is balanced. Further action required will be determined by the inspector after the second water sample result is received.**OUTSTANDING (2025-02-11). The water sample collected on February 11, 2025, had an HPC of 170 CFU/mL. On-site follow-up inspection will be conducted.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on January 02, 2025, had an HPC of 160 CFU/mL in the sample. Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.**OUTSTANDING (2025-02-06). The water sample collected on February 6, 2025, had an HPC of 320 CFU/mL. Initiate treatment of the pool. Send a resample after all the necessary treatments is completed and when the water chemistry is balanced. Further action required will be determined by the inspector after the second water sample result is received.**OUTSTANDING (2025-02-11). The water sample collected on February 11, 2025, had an HPC of 170 CFU/mL. On-site follow-up inspection will be conducted.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow of the swimming pool is too slow and does not achieve the minimum turnover period.REQUIREMENT: Increase the flow and maintain it between the minimum and maximum flow specified in the opening comments.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on January 02, 2025, had an HPC of 160 CFU/mL in the sample. Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.**OUTSTANDING (2025-02-10). The water sample collected on February 6, 2025, had an HPC of 320 CFU/mL. Initiate treatment of the pool. Send a resample after all the necessary treatments is completed and when the water chemistry is balanced. Further action required will be determined by the inspector after the second water sample result is received.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow of the swimming pool is too slow and does not achieve the minimum turnover period.REQUIREMENT: Increase the flow and maintain it between the minimum and maximum flow specified in the opening comments.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on January 02, 2025, had an HPC of 160 CFU/mL in the sample.REQUIREMENT: Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow of the swimming pool is too slow and does not achieve the minimum turnover period.REQUIREMENT: Increase the flow and maintain it between the minimum and maximum flow specified in the opening comments.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on December 05, 2024, had an HPC of 480 CFU/mL in the sample.REQUIREMENT: Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Pool water sample collected on December 19, 2024, had HPC (Heterotrophic Plate Count) enumerated at 1,230 CFU/mL.-Please treat the pool in accordance with the AHS guidelines and submit another water sample. Label as resample, and be aware that a third consecutive unsatisfactory HPC result would lead to pool closure.Here is website for pool water treatment: https://www.albertahealthservices.ca/assets/wf/eph/wf-eph-interpret-microbiological-sample-results-pools.pdf
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow of the swimming pool is too slow and does not achieve the minimum turnover period.REQUIREMENT: Increase the flow and maintain it between the minimum and maximum flow specified in the opening comments.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on December 05, 2024, had an HPC of 480 CFU/mL in the sample.REQUIREMENT: Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow of the swimming pool is too slow and does not achieve the minimum turnover period.REQUIREMENT: Increase the flow and maintain it between the minimum and maximum flow specified in the opening comments.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on July 18, 2024, had an HPC of >57000 CFU/mL in the sample.REQUIREMENT: Begin treatment for the pool. Send a re-sample after you complete necessary treatments and when the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow of the swimming pool is too slow and does not achieve the minimum turnover period.REQUIREMENT: Increase the flow and maintain it between the minimum and maximum flow specified in the opening comments.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow of the swimming pool is too slow and does not achieve the minimum turnover period.REQUIREMENT: Increase the flow and maintain it between the minimum and maximum flow specified in the opening comments.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- **Ongoing Violation** The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
1 infraction
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on May 02, 2024, had an HPC count of 430 CFU/mL.REQUIREMENT: Review the water chemistry and treat the water. Send in a re-sample once treatments are complete and the water chemistry is rebalanced.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on April 19, 2024, had Pseudomonas and an HPC of 1260 CFU/mL in the sample.REQUIREMENT: Review the water chemistry and treat the water. Take a re-sample once treatments are complete and the water chemistry is rebalanced.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Pool water sample collected on 2024-02-15 showed that Pseudomonas aeruginosa was isolated per 100mL.-Please closed and treat the pool in accordance with AHS unsatisfactory pool water result. Take and submit another sample for the swimming pool when the water is treated and chemistry is balanced, please label as resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on February 15, 2024, had an HPC count of 290 CFU/mL.REQUIREMENT: Please review the water chemistry and treat the pool in accordance with AHS unsatisfactory pool water sample. Take another sample for the swimming pool when the water is treated and chemistry is balanced.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on February 01, 2024, had an HPC count of 290 CFU/mL.REQUIREMENT: Please review the water chemistry and treat the pool where needed. Take another sample for the swimming pool when the water is treated and chemistry is balanced.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 16. Are proper testing, monitoring, and other records being properly maintained?
- The pool log does not adequately describe the measurements of chemicals being added during treatment.Please ensure that the pool log is being filled out with as much detail as possible and describes the measurements and types of chemicals being added when treating the pool.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on August 31, 2023 was not processed due to the time of collection not being provided.REQUIREMENT: Take another sample for swimming pool and ensure that the time of collection is included.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Last inspection, it was determined that: "The turnover rate in the swimming pool measured 5.2 hours at the time of inspection."This inspection, the flow meter appeared to be broken - the flow rate could not be determined. REQUIREMENT: Repair or replace the flow meter. Maintain the flow to between 130 and 147 USGPM.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The sample requisition form is not being properly filled out. The swimming pool is maintained at a temperature> 30C, but the previously submitted samples indicate the requisition was filled out to be <30 C. Therefore, this pool should be tested for Pseudomonas aeruginosa.REQUIREMENT: Ensure the pool water sample requisition forms are being properly filled out. If the pool is >30C in temperature, ensure that is marked off on the form.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on June 29, 2023, had a HPC result of 3560 CFU/mL.REQUIREMENT: Review the water chemistry for the pool and balance as needed. An immediate re-sample is not required for the main pool at this time.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Last inspection, it was determined that: "The turnover rate in the swimming pool measured 5.2 hours at the time of inspection."This inspection, the flow meter appeared to be broken - the flow rate could not be determined. REQUIREMENT: Repair or replace the flow meter. Maintain the flow to between 130 and 147 USGPM.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?