Delta by Marriott Grande Prairie Airport - Whirlpool has been inspected 9 times by Alberta Health Services (Environmental Public Health) since July 29, 2024. The most recent inspection, on September 28, 2026, recorded 1 infraction.

4 of 9 inspections on record found no infractions at all. In the past 12 months there were 6 inspections with 5 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 6 times across 5 separate inspections, most recently on September 28, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

9 inspections

  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • A microbiological water sample was collected on September 23, 2026 and submitted to the regional health authority for analysis. The results from this sample are as follows:- Total Coliforms – ABSENT – SATISFACTORY- Pseudomonas Aeruginosa – NOT ISOLATED – SATISFACTORY- 230 cfu/mL of HPC – be advised that a limit of 100 cfu/ml are permitted (for HPC to be present) in any swimming pool.The owner / operator of this facility is requested to conduct the following, namely:1. Super chlorinate this pool and re-balance (if you wish to keep the water within this pool basin). If you wish to drain, disinfect, re-fill, and re-balance this pool basin, super chlorination would then not be necessary. Ensure a re-sample is submitted this week to the regional health authority to determine if the results have improved.
  2. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The bacterial water sample submitted on September 16th was unsatisfactory.- Pseudomonas aeruginosa: present. The whirlpool must be closed, treated, drained, washed, and refilled. The whirlpool must remain closed until a satisfactory water sample has been received.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacterial water sample submitted on September 16th was unsatisfactory.- HPC: 20, 880 CFU/mL.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • A microbiological water sample was submitted to the regional health authority on September 2, 2026. The results of this sample indicate the following;Total coliforms – AbsentHeterotrophic Plate Count - 10 CFU/MLPseudomonas Aeruginosa – ISOLATEDThe owner / operator of this pool is requested to immediately conduct the following, namely:1. Close this pool until further notice2. Drain, scrub, disinfect, re-fill, and re-balance this pool.3. Submit a microbiological water re-sample to the regional health authority for laboratory analysis.4. This pool must remain closed until such time that a satisfactory pool water sample has been achieved.
  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on June24, 2026 indicates presence of HPC 1360 CFU/mL.Ensure Hot Tub is shock chlorinated and water is balanced prior to opening for public.
  6. Monitoring Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Unsatisfactory water result received, collection date September 17, 2025 -HPC - 810 CFU/ml.Resample the hot tub and ensure HPC is below 100 CFU/ml.
  8. Monitoring Inspection

    0 infractions