Skip to content
Loading map…

Edmonton City Hall - Wading Pool

1 Sir Winston Churchill Square NW Edmonton AB T5J 2R7 · Aquatic Facility

Inspection summary

Edmonton City Hall - Wading Pool has been inspected 8 times by Alberta Health Services (Environmental Public Health) since May 15, 2024. The most recent inspection, on May 13, 2026, recorded 1 infraction.

4 of 8 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 4 times across 4 separate inspections, most recently on May 13, 2026. For example: Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 2 times across 2 separate inspections, most recently on May 17, 2024. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

8 inspections

  1. Monitoring Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main drain on the far north of the plaza basin was cracked, and sections of the main drain were damaged. No water was in the basin at time of inspection. Operator confirmed that there is a spare main drain cover that was purchased with the other 4. The spare cover was inspected and noted to be in good condition. Operator confirmed he would remove the damaged cover and replace with the spare. Confirm installation has been completed and provide photos. The pool cannot open until damaged cover is replaced with new main drain.
  2. Risk Management Inspection

    0 infractions

  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 18 July 2025 was unsatisfactory:Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  5. Monitoring Inspection

    0 infractions

  6. Risk Management Inspection

    0 infractions

  7. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • An alarm was illuminated on the controller. This was due to a high ORP reading. Contact service provider to check the controller and confirm if the probe requires calibration or replacement.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • New submerged suction outlets have been installed. Updated anti-entrapment compliance plan must be completed and submitted to for review.
  8. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • An alarm was illuminated on the controller. This was due to a high ORP reading. Contact service provider to check the controller and confirm if the probe requires calibration or replacement.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • New submerged suction outlets have been installed. Updated anti-entrapment compliance plan must be completed and submitted to for review.

Nearby inspected facilities